    • 1、? ABB Switzerland Ltd. All Rights Reserved. ACS 2000 AD Medium Voltage Drives Troubleshooting manual Software Version: LDCI5310 Release Date: 11/29/2011 ? 2/72 Version LDCI5310 Troubleshooting manual ? LDCI5310 ACS 2000 AD 3/72 ABB reserves all rights to this document. Misuse, in particular duplication and forwarding to third parties, is not permitted. This document has been checked with due care and attention. However, should the user find any errors, these should be reported to ABB. ABB aims t

      2、o maintain the most modern standard, therefore, entries in this manual may differ from the actual product. Troubleshooting manual ? 4/72 Version LDCI5310 Troubleshooting manual Table of Contents Table of Contents 4? Faults . 7? Alarms 65? ? LDCI5310 ACS 2000 AD 5/72 Troubleshooting manual If information is required beyond the instructions in this manual, contact ABB as follows: ABB Switzerland Ltd Medium Voltage Drives CH-5300 Turgi, Switzerland Phone:+41 844 845 845 Fax: +41 58 589 2984 E- Trou

      3、bleshooting manual ? 6/72 Version LDCI5310 Troubleshooting manual ? LDCI5310 ACS 2000 AD 7/72 Faults Panel Text AMC: Fault Class 1 Description Class 1 Fault detected in motor control software. Fault reaction is pulse removal (stop motor), opening of MCB and discharging of DC-link Causes Reasons for Class 1 Faults are mainly faults concerning DC-circuit e.g. DC overvoltage and NP- overvoltage. Rectification Check for other related faults in the fault buffer. Each faults results in two records in

      4、fault buffer: fault class (this one) and fault message (other fault texts in this file) FaultClass INU FC1 FaultClass ARU Not Appl Fault Word 183.32: FW Generic Faults Bit B0 Related Parameters Related IO Panel Text AMC: Fault Class 2 Description Class 2 Fault detected in motor control software. Fault reaction is pulse removal (stop motor), if drive was already energized MCB stays closed and DC-link charged Causes Reasons for Class 2 Faults are mainly faults that do not concern the DC circuit e.

      5、g. overspeed, overcurrent, speed measurements Rectification Check for other related faults in the fault buffer. Each faults results in two records in fault buffer: fault class (this one) and fault message (other fault texts in this file) FaultClass INU FC2 FaultClass ARU Not Appl Fault Word 183.32: FW Generic Faults Bit B1 Related Parameters Related IO Panel Text Autorestart Loop Description Trips the drive if the maximum number of auto-restart attempts is exceeded. Causes - Wrong parameter sett

      6、ing . - Depends on the fault that started the auto-restart sequence. Rectification - Check parameter. FaultClass INU FC2 FaultClass ARU Fault Word 183.33: FW1 Generic Faults Bit B1 Related Parameters Related IO Panel Text Autorestart Timeout Description Trips the drive if an auto-restart sequence takes too long. Causes - Wrong parameter setting . - Depends on the fault that started the auto-restart sequence. Rectification - Check parameter. FaultClass INU FC2 FaultClass ARU Fault Word 183.33: FW

      7、1 Generic Faults Bit B0 Related Parameters Related IO Troubleshooting manual ? 8/72 Version LDCI5310 Troubleshooting manual Panel Text CBU Short Circuit Description Short circuit in DC link. Causes A short circuit has been detected in the DC link with MCB in status CLOSED. Rectification - Check MCB status. - Contact ABB Service organisation. FaultClass INU FC1 FT FaultClass ARU Fault Word 183.20: FW Short Circuit Bit B0 Related Parameters Related IO Panel Text CROWBAR FAULT Description When fire

      8、 through happens, crowbar thyristors are not switched on. DC link voltage is not decreasing, or it is decreasing too slowly. Causes - Wrong connection of optical fire through link. - Defective crowbar drive. - Defective crowbar thyristors. Rectification - Check optical fire through link. - Check crowbar drive. - Check crowbar thyristors. - Contact ABB service organization. FaultClass INU FC1 FaultClass ARU Fault Word 183.41: FW2 Other Bit B3 Related Parameters Related IO Panel Text DC OV StatPha

      9、seTest Description DC overvoltage during static phase test. Causes Supply voltage of DC link is too high. Rectification Decrease supply voltage below trip limit. FaultClass INU FC2 FaultClass ARU Fault Word 183.42: FW3 DC LinkVolt Bit B9 Related Parameters Related IO Panel Text DC Overvoltage Description One of the half DC link voltages exceeds the trip level. Causes - ARU fault. - Internal parameter settings. - Defective circuit board. - Communication faulty. Rectification - Check ARU faults. - Check for other related faults. FaultClass INU FC2 FaultClass ARU Fault Word 183.12: FW DC LinkVolt Bit B0 Related Parameters Related IO Panel Text DC OvervoltageMCB Description One of the half DC link voltages exceeds the fault class 1 trip level. Causes - mains supply voltage high . - parameter settings. - defective circuit board. - communication disturbed. Rectification - check supply voltage. - check parameter 186.04. FaultClas

      《abbacs2000变频器硬件故障手册》由会员小**分享,可在线阅读,更多相关《abbacs2000变频器硬件故障手册》请在金锄头文库上搜索。

      点击阅读更多内容
    最新标签
    监控施工 信息化课堂中的合作学习结业作业七年级语文 发车时刻表 长途客运 入党志愿书填写模板精品 庆祝建党101周年多体裁诗歌朗诵素材汇编10篇唯一微庆祝 智能家居系统本科论文 心得感悟 雁楠中学 20230513224122 2022 公安主题党日 部编版四年级第三单元综合性学习课件 机关事务中心2022年全面依法治区工作总结及来年工作安排 入党积极分子自我推荐 世界水日ppt 关于构建更高水平的全民健身公共服务体系的意见 空气单元分析 哈里德课件 2022年乡村振兴驻村工作计划 空气教材分析 五年级下册科学教材分析 退役军人事务局季度工作总结 集装箱房合同 2021年财务报表 2022年继续教育公需课 2022年公需课 2022年日历每月一张 名词性从句在写作中的应用 局域网技术与局域网组建 施工网格 薪资体系 运维实施方案 硫酸安全技术 柔韧训练 既有居住建筑节能改造技术规程 建筑工地疫情防控 大型工程技术风险 磷酸二氢钾 2022年小学三年级语文下册教学总结例文 少儿美术-小花 2022年环保倡议书模板六篇 2022年监理辞职报告精选 2022年畅想未来记叙文精品 企业信息化建设与管理课程实验指导书范本 草房子读后感-第1篇 小数乘整数教学PPT课件人教版五年级数学上册 2022年教师个人工作计划范本-工作计划 国学小名士经典诵读电视大赛观后感诵读经典传承美德 医疗质量管理制度 2