好文档就是一把金锄头!
欢迎来到金锄头文库![会员中心]
电子文档交易市场
安卓APP | ios版本
电子文档交易市场
安卓APP | ios版本

基本消防及生命安全规范架构图文.ppt

39页
  • 卖家[上传人]:桔****
  • 文档编号:586566569
  • 上传时间:2024-09-05
  • 文档格式:PPT
  • 文档大小:483.50KB
  • / 39 举报 版权申诉 马上下载
  • 文本预览
  • 下载提示
  • 常见问题
    • 基本消防及生命安全规范架构图文 Why do we need fire and life safety codes?According to the NFPA, in 2007 there According to the NFPA, in 2007 there were…were…n n530,500 structure fires – one every minute530,500 structure fires – one every minuten n3,000 civilian deaths – one every 2.5 hours 3,000 civilian deaths – one every 2.5 hours n n15,350 civilian injuries – one every 30 minutes15,350 civilian injuries – one every 30 minutesn n$10,600,000,000 in property damage$10,600,000,000 in property damagen nA fire department responded to a fire every 20 A fire department responded to a fire every 20 secondsseconds基本消防及生命安全规范架构图文基本消防及生命安全规范架构图文        Objectivesn nIntroduce the codes that drive fire and life safety compliancen nOverview of fire detection and suppressionn nProvide tools to conduct a basic fire and life safety assessment基本消防及生命安全规范架构图文基本消防及生命安全规范架构图文 Fire Regulations and Codesn nSafety and Health Regulations–OSHA (29 CFR 1910 & 1926)OSHA (29 CFR 1910 & 1926)n nFire and Life Safety Codes–International Building Code (IBC)International Building Code (IBC)–National Fire Protection Association (NFPA)National Fire Protection Association (NFPA)–Municipal RequirementsMunicipal Requirements基本消防及生命安全规范架构图文基本消防及生命安全规范架构图文 Additional Requirementsn nAll codes are minimum requirementsn nInsurance company requirementsn nCompany policiesn nThe Joint Commissionn nState and/or City requirements基本消防及生命安全规范架构图文基本消防及生命安全规范架构图文 How are These Codes Enforcedn nCodes are adopted by reference by Codes are adopted by reference by ordinance.ordinance.n nPlans for remodeling or a new Plans for remodeling or a new construction must be approved by construction must be approved by the authority having jurisdiction the authority having jurisdiction (AHJ) prior to starting work.(AHJ) prior to starting work.– –State Fire Marshal’s OfficeState Fire Marshal’s Office– –Local Fire Department or City Code Local Fire Department or City Code OfficialsOfficials– –Designated Local AHJDesignated Local AHJn nTake Home Message – Know what Take Home Message – Know what code(s) apply to your operationcode(s) apply to your operation   基本消防及生命安全规范架构图文基本消防及生命安全规范架构图文 Which do I follow?n nRemodeling or new construction plans must be approved by authority having jurisdiction (AHJ) prior to starting work–State Fire Marshal’s OfficeState Fire Marshal’s Office–Local Fire Department or City Code Local Fire Department or City Code OfficialsOfficials–Designated Local AHJDesignated Local AHJ基本消防及生命安全规范架构图文基本消防及生命安全规范架构图文 Features of Building Fire and Life Safety                          n nAlarms Alarms n nSprinklersSprinklersn nRated CorridorsRated Corridorsn nExit AccessExit Accessn nNumber of Required Number of Required ExitsExitsn nEgress WidthsEgress Widthsn nOccupant LoadsOccupant Loadsn nElevator RecallElevator Recalln nFire Rated Doors & Fire Rated Doors & FramesFramesn nSmoke ControlSmoke Controln nRated StairwellsRated Stairwellsn nFireproofing Fireproofing RequirementsRequirementsn nElectrical SafetyElectrical Safetyn nConstruction Construction CombustibilityCombustibilityn nFire and Smoke Fire and Smoke DampersDampersn nEmergency PowerEmergency Powern nRoof AssembliesRoof Assemblies基本消防及生命安全规范架构图文基本消防及生命安全规范架构图文 Fire Alarm Systemsn nPlay an Essential Role in Protecting Property and Lives From Fire.n nProtection Goals Governs System Selection– –Building Occupant SafetyBuilding Occupant Safety– –Satisfy Building Codes or AHJ Satisfy Building Codes or AHJ RequirementsRequirements– –Property ProtectionProperty Protection– –First Responder SafetyFirst Responder Safety– –Environmental ProtectionEnvironmental Protection– –CombinationCombination   基本消防及生命安全规范架构图文基本消防及生命安全规范架构图文 Fire Alarm Systemsn nIBC references NFPA 72 for installation and maintenancen nNFPA 72 – National Fire Alarm Coden nBasic Components–PanelPanel–DetectionDetection–Manual AlarmManual Alarm–NotificationNotification–Off-Premises Connection for SupervisionOff-Premises Connection for Supervision基本消防及生命安全规范架构图文基本消防及生命安全规范架构图文 Fire Alarm Systemsn nFire Alarm System Will Provide Three Types of Signals– –AlarmAlarm– –Trouble – indicates a fault in a Trouble – indicates a fault in a monitoring circuit or component of the monitoring circuit or component of the fire alarm systemfire alarm system§ §Bad smoke detectorBad smoke detector§ §Ground faultGround fault– –Supervisory – indicates a problem with Supervisory – indicates a problem with other fire protection systems being other fire protection systems being monitored by the fire alarm systemmonitored by the fire alarm system§ §Water valve to sprinkler system closedWater valve to sprinkler system closed§ §Clean agent system problemClean agent system problemAlarmAlarmSupervisorySupervisoryTroubleTrouble基本消防及生命安全规范架构图文基本消防及生命安全规范架构图文 Off-Premises Connection for Supervision基本消防及生命安全规范架构图文基本消防及生命安全规范架构图文 Common Fire Detectionn nSmoke Detector§ §IonizationIonization§ §PhotoelectricPhotoelectricn nHeat Detectors§ §Fixed TemperatureFixed Temperature§ §Rate-of-RiseRate-of-Rise基本消防及生命安全规范架构图文基本消防及生命安全规范架构图文 Manual Pull Stationsn nManual pull devices will be located on the walln nActivated by pulling on a handlen nSends signal to building’s fire alarm system which places the building into alarm基本消防及生命安全规范架构图文基本消防及生命安全规范架构图文 Notification Appliancesn nAudible alarms (How loud is loud enough?)–Public – SPL must be 5 dB above any Public – SPL must be 5 dB above any ambient noise that lasts 60 sec. or ambient noise that lasts 60 sec. or more, or 15 dB above the 24-hr more, or 15 dB above the 24-hr average, whichever is greateraverage, whichever is greater–Sleeping quarters – Minimum of 75 Sleeping quarters – Minimum of 75 dBAdBA基本消防及生命安全规范架构图文基本消防及生命安全规范架构图文 Notification Appliancesn nVoice Communication–Better to have a larger number of Better to have a larger number of lower SPL units vs. a few very lower SPL units vs. a few very loud unitsloud units–Intelligibility can be a problemIntelligibility can be a problem基本消防及生命安全规范架构图文基本消防及生命安全规范架构图文 Notification Appliancesn nVisual alarms –Primarily intended to augment Primarily intended to augment audible alarmsaudible alarmsn nCommon Locations of Visual Alarms–CorridorsCorridors–Meeting roomsMeeting rooms–RestroomsRestrooms–Enclosed elevator lobbiesEnclosed elevator lobbies基本消防及生命安全规范架构图文基本消防及生命安全规范架构图文 Fire Alarm System Interfacesn nHeating Ventilation and Air Conditioning–Duct detectorsDuct detectors–AHU shut-down AHU shut-down n nSprinkler water flow alarmsn nMagnetic lock release mechanismsn nDoor unlocking devicesn nElevator recalln nStairwell pressurization基本消防及生命安全规范架构图文基本消防及生命安全规范架构图文 System Reliabilityn nBased on Four Elements– –DesignDesign– –EquipmentEquipment§ §Underwriters LaboratoriesUnderwriters Laboratories§ §Factory Mutual GlobalFactory Mutual Global– –InstallationInstallation– –MaintenanceMaintenance§ §Inspection, Testing, and Maintenance are crucialInspection, Testing, and Maintenance are crucial§ §Unfortunately, some problems may be identified Unfortunately, some problems may be identified after the previous three have been completedafter the previous three have been completed基本消防及生命安全规范架构图文基本消防及生命安全规范架构图文 Fire Suppressionn nWater Based Suppressionn nClean Agent Systemsn nFire Extinguishers基本消防及生命安全规范架构图文基本消防及生命安全规范架构图文 Water Based Suppressionn nWet-Pipe–System contains water under pressure at System contains water under pressure at all timesall times–Series of closed sprinkler headsSeries of closed sprinkler heads–Heat activates sprinkler head Heat activates sprinkler head –Water is discharged immediately Water is discharged immediately * Not recommended if system could be exposed to temperatures * Not recommended if system could be exposed to temperatures below 40ºFbelow 40ºF基本消防及生命安全规范架构图文基本消防及生命安全规范架构图文 Wet-Pipe System1.1.Main valveMain valve2.2.Alarm check valveAlarm check valve3.3.Fire department check Fire department check valvevalve4.4.Fire department Fire department connectionconnection5.5.Water motor alarmWater motor alarm6.6.Sprinkler headSprinkler head7.7.Inspector’s test valveInspector’s test valve基本消防及生命安全规范架构图文基本消防及生命安全规范架构图文 Wet-Pipe Systemn nOnly the sprinkler heads heated by the fire activateOnly the sprinkler heads heated by the fire activaten nFire sprinklers spray 18 gallons of water per minuteFire sprinklers spray 18 gallons of water per minuteSprinkler headSprinkler headAs temperature rises As temperature rises the bulb will shatterthe bulb will shatterWater is Water is released released and and deflected in deflected in a spray a spray patternpattern基本消防及生命安全规范架构图文基本消防及生命安全规范架构图文 Sprinkler Color Codes and RatingsColorSprinkler ClassificationTemperature RatingRedOrdinary135-170Yellow/GreenIntermediate175-225BlueHigh250-300PurpleExtra High325-375BlackUltra High500-575基本消防及生命安全规范架构图文基本消防及生命安全规范架构图文 Field Method for Temporary Stoppage of Sprinkler Head基本消防及生命安全规范架构图文基本消防及生命安全规范架构图文 Dry-Pipe Systemn nSystem contains air under pressureSystem contains air under pressure– –Compressor on system keeps pressure upCompressor on system keeps pressure upn nSprinkler heads hold the pressureSprinkler heads hold the pressuren nA dry-pipe valve holds back the water supplyA dry-pipe valve holds back the water supplyn nValve opens when pressure falls below a Valve opens when pressure falls below a predetermined levelpredetermined leveln nSprinkler head activation – pressure drop – valve Sprinkler head activation – pressure drop – valve opens – water sent to all heads –  water discharged opens – water sent to all heads –  water discharged from activated sprinkler head(s)from activated sprinkler head(s)* Recommended for areas that could experience freezing * Recommended for areas that could experience freezing temperaturestemperatures基本消防及生命安全规范架构图文基本消防及生命安全规范架构图文 How do Dry-Pipe Systems Work?1.1.Heat ActivatedHeat Activated2.2.Pressure DropPressure Drop5.5.Water Discharges from activated headWater Discharges from activated head4.4.Water sent to all sprinkler headsWater sent to all sprinkler heads3.3.Valve OpensValve Opens基本消防及生命安全规范架构图文基本消防及生命安全规范架构图文 Dry-Pipe System1.1.Supply check valveSupply check valve2.2.Main valveMain valve3.3.Dry pipe valveDry pipe valve4.4.Fire department Fire department check valvecheck valve5.5.Fire department Fire department connectionconnection6.6.Water motor alarmWater motor alarm7.7.Sprinkler headSprinkler head8.8.Inspector’s test Inspector’s test valvevalve基本消防及生命安全规范架构图文基本消防及生命安全规范架构图文 Pre-action Systemn nSystem contains air under pressureSystem contains air under pressure– –Compressor on system keeps pressure upCompressor on system keeps pressure upn nWater held back by pre-action valveWater held back by pre-action valven nSystem equipped with supplemental detectionSystem equipped with supplemental detectionn nOperation of detection system allows pre-action Operation of detection system allows pre-action valve to open and water fills the systemvalve to open and water fills the systemn nWater not discharged until fire has generated Water not discharged until fire has generated sufficient heat to activate a sprinkler headsufficient heat to activate a sprinkler head* * Typically found in computer rooms and museumsTypically found in computer rooms and museums基本消防及生命安全规范架构图文基本消防及生命安全规范架构图文 How do Pre-Action Systems Work?1.1.Smoke DetectedSmoke Detected5.5.Water Discharges from activated headWater Discharges from activated head4.4.Water sent to all sprinkler headsWater sent to all sprinkler heads3.3.Valve OpensValve Opens基本消防及生命安全规范架构图文基本消防及生命安全规范架构图文 Pre-action System1.1.Supply check valveSupply check valve2.2.Main valveMain valve3.3.Water control or deluge Water control or deluge valvevalve4.4.Fire department check Fire department check valvevalve5.5.Fire department Fire department connectionconnection6.6.Water motor alarmWater motor alarm7.7.Sprinkler head (closed)Sprinkler head (closed)8.8.DetectorDetector9.9.Electrical bellElectrical bell10.10.Manual release stationManual release station11.11.Control panelControl panel12.12.Inspector’s test valveInspector’s test valve基本消防及生命安全规范架构图文基本消防及生命安全规范架构图文 Fire Pumpsn nFire pumps are utilized when the hydraulic demand exceeds public supply capacityn nComponents –Pump and motorPump and motor–ControllersControllers–Jockey pumpJockey pump–Water tankWater tank基本消防及生命安全规范架构图文基本消防及生命安全规范架构图文 Water Supplyn nStandpipe System– –Class I – 2 ½ inch hose connection Class I – 2 ½ inch hose connection intended for fire department useintended for fire department use– –Class II – 1 ½ inch hose Class II – 1 ½ inch hose connections intended for first-aid connections intended for first-aid fire fightingfire fighting– –Class III – Provided with both 2 ½ Class III – Provided with both 2 ½ inch and 1 ½ inch hose inch and 1 ½ inch hose connectionsconnectionsn nFire Department Connection基本消防及生命安全规范架构图文基本消防及生命安全规范架构图文 Suppression Without Watern nHalon – NFPA 12A–Being phased out per 1987 Being phased out per 1987 Montreal ProtocolMontreal Protocoln nCarbon Dioxide – NFPA 12n nClean Agent – NFPA 2001–Inert gas formulationInert gas formulation* These systems are often not recognized as * These systems are often not recognized as allowable substitute for water suppressionallowable substitute for water suppression基本消防及生命安全规范架构图文基本消防及生命安全规范架构图文 Fire Extinguishersn nNFPA 10 standard for portable fire extinguishersn nSelect appropriate extinguisher for area– –Class A, B, C, D, and KClass A, B, C, D, and Kn nIdentify hazard occupancy– –Light HazardLight Hazard§ §Offices, schools, assembly hallsOffices, schools, assembly halls– –Ordinary HazardOrdinary Hazard§ §Mercantile storage, parking garagesMercantile storage, parking garages– –High HazardHigh Hazard§ §Woodworking area, warehousesWoodworking area, warehouses基本消防及生命安全规范架构图文基本消防及生命安全规范架构图文 Conducting a Basic Assessmentn nDetermine Your Building Occupancy Determine Your Building Occupancy Type FirstType Firstn nIBC Occupancy ClassificationsIBC Occupancy Classifications– –Assembly: Group A-1, A-2, A-3, A-4 and A-5Assembly: Group A-1, A-2, A-3, A-4 and A-5– –Business: Group BBusiness: Group B– –Educational: Group EEducational: Group E– –Factory and Industrial: Groups F-1 and F-2Factory and Industrial: Groups F-1 and F-2– –High Hazard: Groups H-1, H-2, H-3, H-4, and H-5High Hazard: Groups H-1, H-2, H-3, H-4, and H-5– –Institutional: Group I-1, I-2, I-3 and I-4Institutional: Group I-1, I-2, I-3 and I-4– –Mercantile: Group MMercantile: Group M– –Residential: Groups R-1, R-2, R-3 and R-4Residential: Groups R-1, R-2, R-3 and R-4– –Storage: Groups S-1 and S-2Storage: Groups S-1 and S-2– –Utility and Miscellaneous: Group UUtility and Miscellaneous: Group U基本消防及生命安全规范架构图文基本消防及生命安全规范架构图文 Conducting a Basic Assessmentn nAdditional Detailed Requirements Based on Use and Occupancy– –Covered Mall BuildingsCovered Mall Buildings– –High-Rise BuildingsHigh-Rise Buildings– –AtriumsAtriums– –Underground BuildingsUnderground Buildings– –Motor-Vehicle-Related OccupanciesMotor-Vehicle-Related Occupancies– –Motion Picture Projection RoomsMotion Picture Projection Rooms– –Stages and PlatformsStages and Platforms– –Special Amusement BuildingsSpecial Amusement Buildings– –Aircraft-Related OccupanciesAircraft-Related Occupancies– –Combustible StorageCombustible Storage– –Hazardous MaterialsHazardous Materials– –Drying RoomsDrying Rooms基本消防及生命安全规范架构图文基本消防及生命安全规范架构图文 Know Your Buildingn nOnce occupancy is determined codes will give you guidance–What type of construction is required?What type of construction is required?–Is a sprinkler system required?Is a sprinkler system required?–Is a fire alarm system required?Is a fire alarm system required?–Exiting and egress?Exiting and egress?–Emergency power required?Emergency power required?–Is a smoke control system required?Is a smoke control system required?–Is a standpipe system required?Is a standpipe system required?基本消防及生命安全规范架构图文基本消防及生命安全规范架构图文 Referencesn nInternational Building Code, International Code Counciln nNational Fire Protection Associationn nThe Joint Commission基本消防及生命安全规范架构图文基本消防及生命安全规范架构图文 。

      点击阅读更多内容
      关于金锄头网 - 版权申诉 - 免责声明 - 诚邀英才 - 联系我们
      手机版 | 川公网安备 51140202000112号 | 经营许可证(蜀ICP备13022795号)
      ©2008-2016 by Sichuan Goldhoe Inc. All Rights Reserved.