毕业设计(论文)_某综合楼火灾自动报警及消防联动系统控制.doc
45页摘 要随着我国经济建设的迅速发展,人民生活水平不断提高,城市用地日益紧张,促使建筑物正朝着高层化、密集化方向发展高层建筑的特点决定其火灾的危险性和高层建筑的火灾自动报警系统的重要性,一套完整的火灾自动报警系统是高层建筑发生火灾时人们生命财产的有利保障,是能否快速准确地发现火情,把火灾扑灭在萌芽状态的关键所在, 本设计主要由下面几个部分组成:(1)火灾自动报警系统该大楼的自动报警系统由火灾探测器、区域显示器和集中报警器组成在一层设置消防控制中心并在每层设区域显示器2)消防通讯系统火灾事故广播与公共广播结合使用事故广播功放设置一主一备两台,并且功率满足要求采用总线制设备,每路设控制模块,每个控制模块可控制40个3w的扬声器消防专用 独立设置消防通讯网络系统在消防控制室、各值班室、主要出入口处,设置消防专用 消防专用 距地1.5m,并能和市119火警 线接通3)安全疏散和防排烟系统火灾发生时由烟感器感知,并在防灾中心显示所在分区以手动操作为原则将排烟口开启,排烟风机与排烟口的操作连锁启动,人员开始疏散火势扩大后,排烟风道中的阀门在温度达到280℃时关闭,停止排烟,这时,火灾层的人员全部疏散完毕。
4)联动控制系统消防泵、喷洒泵启动,防烟和排烟风机启动、切除非消防电源、电梯迫降、防火卷帘的下降逻辑编制,任何确认火灾信号均联动消防设施动作在系统设计上,自动确认,用两组探测器或两种不同类别的火灾探测器同时报警后确定确认火灾后,切除非消防电源和电梯迫降;火灾报警后应停止空调送风,关闭电动防火阀,启动有关部位的防烟和排烟风机、排烟阀等,并接收反馈信号关 键 词:自动报警 消防通讯 安全疏散和防排烟 联动控制 AbstractWith the rapid development of China's economic construction, people's rising living standards, urban land increasingly tense, to promote high-level of the building is moving, the direction of intensive development. Determine the characteristics of high-rise building fire risk and high-rise building of the importance of automatic fire alarm system, a complete automatic fire alarm system is a high-rise building fire when it was beneficial to protect life and property, is the ability to quickly and accurately find fire, the fire is extinguished the key in the bud, the design mainly consists of the following components: (1)Fire alarm system The building's automatic fire alarm system consists of detectors, regional centralized alarm display and composition. Set in a layer of fire control center located in each area displays. (2)The Fire Services Communication System System Fire combination of broadcasting and public broadcasting. Accident radio amplifier set a preparation of a master of two, and power to meet the requirements. Equipment using the bus system, each set control module, each control module can control 40 3w speakers. Independent set fire dedicated telephone communication network system. In the fire control room, the duty room, the main entrance, set fire special phone. Dedicated telephone from the fire to 1.5m, and can fire 119 telephone lines and the city connected. (3)Safe evacuation and smoke control systemFire by the smoke detector sensing, and the partition shown in the Disaster Prevention Center. To manually turn on the principle of the exhaust port, exhaust fan and the exhaust port of the operating chain started, people began to evacuate. The spread of fire, the smoke in the air duct in the valve closed when the temperature reaches 280 ℃, stop smoke, this time, fire personnel evacuated finished floor. (4)Coordinated control system Fire pump, sprinkler pump starts, smoke and exhaust fan starts, the removal of non-fire power, the elevator landing, fire shutter down logic preparation, any confirmation of fire signal fire facilities are linked actions. In the system design, automatic recognition, with two sets of two different types of detectors or fire detectors alarm at the same time determined. Confirmed after the fire, the removal of non-fire power and the elevator landing; fire alarm should stop after the air supply, turn off the electric fire damper, start the relevant parts of the smoke and exhaust fan, exhaust valves, etc., and receive feedback signals.Key words: Automatic alarm Fire communications Safe evacuation and smoke control coordinated control目 录1 绪 论 1选题的目的和意义 1国内外研究现状简述 1所采用的研究方法和手段 22 火灾自动报警系统 32.1 防火类别及等级的确定 32.2 该大楼火灾自动报警系统结构选型 32.2.1 火灾自动报警系统结构类型 32.2.2 该大楼结构选型 42.3 报警区域及探测区域的划分 52.3.1 探测区域划分规定 5 该综合大楼的探测区域的划分 52.4 火灾探测器的选择与设计 6火灾探测器的设置要求 6火灾探测器的设置部位 7火灾探测器的数量计算 72.5 手动火灾报警按钮、消火栓按钮的设置 92.6 区域显示器的布置 92.7 水流指示器的布置 93 消防通讯系统 103.1 消防广播系统 103.1.1 火灾应急广播扬声器的设置要求 103.1.2 火灾应急广播扬声器的设计布置计算 113.1.3 火灾应急广播扬声器的设置 123.2 消防专用 系统 133.2.1 消防专用 设计要求 133.2.2 消防专用 的布置 144 安全疏散与防排烟系统 154.1 安全疏散诱导与防排烟系统的基本概念 154.2 应急照明系统设计 164.2.1 应急照明设置要求 164.2.2 应急疏散照明设置 174.3 消防电梯 174.3.1 消防电梯的设置要求 174.3.2 消防电梯的设置 184.4 排烟系统 194.4.1 高层建筑的排烟方式的分类 194.4.2 排烟设备的安装设置 204.5 防烟系统 224.5.1 防烟系统分类 224.5.2 防烟设备的的安装设置 244.6 防排烟系统的设置和监控 244.6.1 防排烟系统的设置 244.6.2 防排烟设备的监控 255 联动控制系统 285.1 消防联动控制系统的基本概念 285.2 防火卷帘的联动控制 295.3 喷淋泵联动控制 305.4 正压风机控制 325.5 排烟风机控制 336 系统供电接地和布线 356.1 系统供电设计 356.2 系统接地设计 356.3 系统布线设计 367 结论与展望 38致 谢 39参考文献 401 绪 论随着社会经济的快速发展,高层建筑不断涌现,火灾的危害性也越来越大了。
主要原因有四个:①建筑物装饰装修的档次越来越高,而在装饰装修材料中有很多的有机易燃物,发生火灾的几率增加了②新建的建筑物内一般都设置有各种管道和竖井,他们像一个个直立的烟囱,一旦失火,火势借助“烟囱效应”蔓延很快③由于楼层较高,建筑物内的人员和物资难以疏散④由于楼与楼之间的距离较小,消防车辆难以接近,消防扑救也相当困难所以在现代的建筑物内建立一个先进的、行之有效的火灾自动报警及消防联动控制系统是非常重要的 纵观一百多年来,火灾自动报警技术主要经历了多个发展阶段:最初阶段是用一些简单的分立元件构成的火灾自动报警系统,从十九世纪四十年代一直延续到本世纪四十年代,这期间感温探测器占主导地位,火灾自动报警系统的发展处于初级阶段1847年美国缅因大学教授Farmer等研究出世界上第一台用于城镇的火灾报警发送装置,1852年成功安装在波士顿1874年英国安装了世界上第一套水喷淋装置,1890年英国科学家研制成功感温式火灾探测器,到1896年几种不同类型的定温火灾探测装置相继研制成功了,并得到实际应用从八十年代开始至今总线制火灾自动报警系统蓬勃兴起,它同以前的产品相比有了很大的飞跃,布线工作显著减少,安装调试变的容易,降低了安装。