好文档就是一把金锄头!
欢迎来到金锄头文库![会员中心]
电子文档交易市场
安卓APP | ios版本
电子文档交易市场
安卓APP | ios版本

斯坦福发电机SX460型AVR说明书.pdf

4页
  • 卖家[上传人]:油条
  • 文档编号:45895304
  • 上传时间:2018-06-20
  • 文档格式:PDF
  • 文档大小:85.30KB
  • / 4 举报 版权申诉 马上下载
  • 文本预览
  • 下载提示
  • 常见问题
    • TD_SX460.GB_05.03_02 SX460 AUTOMATIC VOLTAGE REGULATOR (AVR) SPECIFICATION, INSTALLATION AND ADJUSTMENTS General description Technical specification SX460 is a half-wave phase-controlled thyristor type Automatic Voltage Regulator (AVR) and forms part of the excitation system for a brush-less generator. In addition to regulating the generator voltage, the AVR circuitry includes under-speed and sensing loss protection features. Excitation power is derived directly from the generator terminals. Positive voltage build up from residual levels is ensured by the use of efficient semiconductors in the power circuitry of the AVR. The AVR is linked with the main stator windings and the exciter field windings to provide closed loop control of the output voltage with load regulation of +/- 1.5%. In addition to being powered from the main stator, the AVR also derives a sample voltage from the output windings for voltage control purposes. In response to this sample voltage, the AVR controls the power fed to the exciter field, and hence the main field, to maintain the machine output voltage within the specified limits, compensating for load, speed, temperature and power factor of the generator. A frequency measuring circuit continually monitors the generator output and provides output under-speed protection of the excitation system, by reducing the output voltage proportionally with speed below a pre-settable threshold. A manual adjustment is provided for factory setting of the under frequency roll off point, (UFRO). This can easily be changed to 50 or 60 Hz in the field by push- on link selection. Provision is made for the connection of a remote voltage trimmer, allowing the user fine control of the generator's output. INPUT Voltage Jumper selectable 95-132V ac or 190-264V ac Frequency 50-60 Hz nominal Phase 1 OUTPUT Voltage max 90V dc at 207V ac input Current continuous 4 A dc Intermittent 6 A for 10 secs Resistance 15 ohms minimum REGULATION +/- 1.5% (see note 1) THERMAL DRIFT 0.05% per deg. C change in AVR ambient (note 2) TYPICAL SYSTEM RESPONSE AVR response 20 ms Filed current to 90% 80 ms Machine Volts to 97% 300 ms EXTERNAL VOLTAGE ADJUSTMENT +/-10% with 1 k ohm 1 watt trimmer (see note 3) UNDER FREQUENCY PROTECTION Set point 95% Hz (see note 4) Slope 170% down to 30 Hz UNIT POWER DISSIPATION 10 watts maximum BUILD UP VOLTAGE 4 Volts @ AVR terminals ENVIRONMENTAL Vibration 20-100 Hz 50mm/sec 100Hz – 2kHz 3.3g Operating temperature -40 to +70°C Relative Humidity 0-70°C 95% (see note 5) Storage temperature -55 to +80°C NOTES 1. With 4% engine governing 2. After 10 minutes. 3. Applies to Mod status F onwards. Generator de-rate may apply. Check with factory. 4. Factory set, semi-sealed, jumper selectable 5. Non condensing. DESIGN DETAIL TD_SX460.GB_05.03_02 The main functions of the AVR are: Potential Divider and Rectifier takes a proportion of the generator output voltage and attenuates it. This input chain of resistors includes the range potentiometer and hand trimmer which adjust the generator voltage. A rectifier converts the a.c. into d.c. for further processing. The Amplifier (Amp) compares the sensing voltage to the Reference Voltage and amplifies the difference (error) to provide a controlling signal for the power devices. The Ramp Generator and Level Detector and Driver infinitely control the conduction period of the Power Control Devices and hence provides the excitation system with the required power to maintain the generator voltage within specified limits. The Stability Circuit provides adjustable negative ac feedback to ensure good steady state and transient performance of the control system. The Low Hz Detector measures the period of each electrical cycle and causes the reference voltage to be reduced approximately linearly with speed below a presettable threshold. A Light Emitting Diode gives indication of underspeed running. The Synchronising circuit is used to keep the Ramp Generator and Low Hz Detector locked to the generator waveform period. The Low Pass Filter prevents distorted waveforms affecting the operation of the AVR. Power Control Devices vary the amount of exciter field current in response to the error signal produced by the Amplifier. Suppression components are included to prevent sub cycle voltage spikes damaging the AVR components and also to reduce the amount of conducted noise on the generator terminals. The Power Supply provides the required voltages for the AVR circuitry. SuppressionLow Pass FilterSynchronising Ciruit Low Hz Detection Power Control Devices Level Detector & Driver Reference Voltage Stability Circuit Potential Divider & Rectifier Power supplyRamp GeneratorGeneratorAmp Voltage Sensing Hand Trimmer Exciter Field FITTING AND OPERATING TD_SX460.GB_05.03_02 SUMMARY OF AVR CONTROLS CONTROL FUNCTION DIRECTION VOLTS TO ADJUST GENERATOR OUTPUT VOLTAGE CLOCKWISE INCREASES OUTPUT VOLTAGE STABILIT。

      点击阅读更多内容
      关于金锄头网 - 版权申诉 - 免责声明 - 诚邀英才 - 联系我们
      手机版 | 川公网安备 51140202000112号 | 经营许可证(蜀ICP备13022795号)
      ©2008-2016 by Sichuan Goldhoe Inc. All Rights Reserved.