罗氏电化学发光免疫分析仪项目推荐稀释比例.doc
5页Claudia Schäfer, Global Customer Support, Penzberg 4486 MODULAR ANALYTICS E170, cobas e 601, cobas e 602, Elecsys® 2010, cobas e 411 Elecsys® Dilution Recommendations Autodilution possible for bold mentioned dilution ratios Dilution not necessary due to the broad measuring range or not possible e.g. can not be diluted because of changing in the concentration of the binding proteins alters this equilibrium.@ The autoantibodies are heterogeneous and this gives rise to non-linear dilution phenomena.* Please check the package insert.STAT for Elecsys 2010, cobas e 411, cobas e 601 (SW version 04-03 onwards) and cobas e 602# Diluent Universal can be used to dilute the samples. Auto-dilution is not possible as assay uses a three-step method. Use Elecsys® Diluent Universal for automatic sample predilution. Autodilution not possible.Diluent ratio Version 4.6May 20111/5Reagent typeTestRecommended dilution ratiosConcentration of diluted sample must be FT3 FT4 T3 T4 TSH1:10 with Diluent MA> 10 µIU/ml T-uptake TG1:5 with Diluent Universal> 50 ng/ml Anti-TG@ Anti-TPO@ 1:5 with Diluent Universal manually> 100 IU/mlThyroid Function TestAnti-TSHR1:5 or 1:10 with Anti-TSHR negative human sera*> 4 IU/lCK-MB (STAT)1:2 with Diluent MA> 50 ng/ml Digoxin1:2 with Diluent Universal> 2.5 ng/ml>3.2 nmol/l Digitoxin1:2 with Diluent Universal> 30 ng/ml> 39 nmol/l Myoglobin (STAT)1:10 with Diluent Universal> 50 ng/ml proBNP II (STAT only cobas e 601/2)1:2 with Diluent Universal> 15000 pg/ml > 1770 pmol/l Troponin I (STAT)1:10 with Diluent MA> 3 µg/l > 3 ng/ml Troponin T (STAT)1:10 with Diluent Universal> 1 µg/l > 1 ng/mlCardiacTroponin T hs (STAT )1:10 with Diluent MA> 1000 ng/l ACTH Cortisol1:10 with Diluent Universal * (for urine samples)> 50 nmol/l > 1.8 µg/dl DHEA-S1:5 with low concentrated human sera*> 1.5 µmol/l > 45 µg/dl Estradiol II1:5 with Diluent MA> 1835 pmol/l > 500 pg/ml FSH HCG+ HCG (STAT)1:100 with Diluent Universal*> 100 mIU/mlHormonesLHClaudia Schäfer, Global Customer Support, Penzberg 4486 MODULAR ANALYTICS E170, cobas e 601, cobas e 602, Elecsys® 2010, cobas e 411 Elecsys® Dilution RecommendationsDiluent ratio Version 4.7August 20112/5Reagent typeTestRecommended dilution ratiosConcentration of diluted sample must be Progesterone II1:10 with Diluent Estradiol / Progesterone *> 6 nmol/l > 2 ng/ml Prolactin II1:10 with Diluent Universal> 50 µIU/ml, > 2.4 ng/ml SHBG1:10 with Diluent MA> 20 nmol/l Testosterone II C-Peptide (serum and urine)1:10 with Diluent MA> 4 ng/ml > 1.3 nmol/lDiabetesInsulin PlGFPreeclampsia sFLT-1* Free ßhCG1:10 with Diluent Universal> 19 IU/lDown`s syndrome screeningPAPP-A1:10 with Diluent Universal> 500 mIU/lAFP1:50 with Diluent Universal> 20 U/ml, > 24 ng/ml CA 125 II1:5 with Diluent Universal> 1000 U/ml CA 15-3 II 1:10 with Diluent Universal (only 1:10 possible on E170 / cobas e 601/2)> 30 U/mlCA 19-91:10 with Diluent Universal> 50 U/ml CA 72-41:2 with Diluent Universal> 150 U/ml CEA1:50 with Diluent Universal> 20 ng/ml Cyfra 21-11:2 with Diluent Universal> 250 ng/ml HE41:20 with Diluent MA> 75 pmol/l NSE1:2 with diluent NSE > 50 ng/ml Free PSA Total PSA1:50 with Diluent Universal> 2 ng/mlTumor MarkerS 1001:5 with S 100 analyt free human serum or CalSet 1> 1 µg/lFree ßhCG1:10 with Diluent Universal> 19 IU/lDown`s syndrome screeningPAPP-A1:10 with Diluent Universal> 500 mIU/lVitamin B121:2 with Diluent Universal> 1000 pg/ml, >738 pmol/l Ferritin1:50 with Diluent Universal> 40 ng/ml Folate III1:2 with Diluent Universal> 10 ng/ml, > 22.7 nmol/lAnaemiaRBC Folate1:2 with 0.2% ascorbic acid solution>16.2 nmol/l > 8 ng/ml ß-CrossLaps hGH1:2 with Diluent Universal> 25 ng/ml N-MID Osteocalcin1:5 with Diluent Universal> 60 ng/ml Total P1NP1:2 with Diluent Universal> 100 µg/l PTH (STAT) PTH (1-84)1:2 with Diluent Universal> 1150 pg/nl > 122 pmol/lBoneVitamin D total1:2 with Diluent Universal> 35 ng/ml > 87.5 nmol/l VariaIgE II1:20 with Diluent Universal> 125 IU/ml, > 300 ng/ml Rheumatoid Anti-CCP1:2 to 1:5 with neg. human Claudia Schäfer, Global Customer Support, Penzberg 4486 MODULAR ANALYTICS E170, cobas e 601, cobas e 602, Elecsys® 2010, cobas e 411 Elecsys® Dilution RecommendationsDiluent ratio Version 4.7August 20113/5Reagent typeTestRecommended dilution ratiosConcentration of diluted sample must be Arthritisserum pool* Brahms PCT1:4 with neg. human sera> 1.0 ng/mlSepsis IL 61:10 with Diluent MA> 50 pg/ml Anti-HAVwith Diluent Hepatitis A > 20 IU/l Anti-HAV IgM # Anti-HBc#* Anti-HBc IgM # Anti-HBe#* HBeAg#* Anti-HBs1:100 with Diluent Universal> 10 IU/ml HBsAg / HBsAg II* HBsAg II quant1:100 or 1:400 depending on the used system with Diluent HepB*Infectious DiseasesAnti-HCV* RetrovirusesHIV Ag* HIV combi* HIV combi PT* CMV IgG1:20 with Diluent Universal 15 U/ml CMV IgG Avidity1:20 with Diluent Universal* CMV IgM* HSV-1 IgG* HSV-2 IgG* Rubella IgG1:20 with Diluent Universal> 10 IU/l Rubella IgM* Toxo IgG1:20 with Diluent Universal>。