常用建筑材料热物理性能计算参数.doc
24页附件1常用建筑材料热物理性能计算参数取值分类材料名称干密度(kg/m3)计算参数导热系数λ[W/(m·K)]蓄热系数S(周期24h)[W/(m2·K)]比热容C[kJ/(kg·K)]混凝土钢筋混凝土25001.7417.200.92碎石、卵石混凝土23001.5115.360.9221001.2813.570.92沥青混凝土21001.0516.391.68烧结陶粒混凝土1351~14500.496.430.841451~15500.577.190.841551~16500.668.010.841651~17500.768.810.841751~18500.879.740.841851~19501.0110.700.84全轻混凝土551~6500.162.701.05651~7500.183.091.05751~8500.203.481.05851~9500.233.961.05951~10500.264.441.051051~11500.284.831.051151~12500.315.311.051251~13500.365.961.05泡沫混凝土3000.081.421.054000.101.811.055000.122.201.056000.142.591.057000.183.161.058000.213.641.059000.244.121.0510000.274.591.05砂浆水泥砂浆18000.9311.371.05混合砂浆17000.8710.751.05无机保温砂浆≤3300.071.261.05≤4000.0851.611.05≤5000.101.951.05≤6000.122.341.05胶粉聚苯颗粒保温浆料180~2500.060.95砌块及砌体普通烧结页岩空心砖砌体8000.541.05蒸压加气混凝土砌块426~5250.142.361.05526~6250.162.751.05626~7250.183.151.05726~8250.203.541.05烧结页岩多孔砖砌体14000.587.851.05节能型烧结页岩空心砌块(孔排数≥9排,孔洞率≥50%)砌体≤8000.253.901.05801~9004.13厚壁型烧结页岩空心砌块(外壁厚≥25mm孔排数≥7排,孔洞率≥45%)砌体801~9000.304.531.05无机复合烧结页岩空心砖(规格:长200mm,宽190mm,厚115mm,填充厚度为40mm、密度等级为B03级及以下的泡沫混凝土)砌体≤8000.264.231.05烧结陶粒混凝土小型空心砌块砌体(孔排数≥3排)801~9000.284.37建筑板材防水珍珠岩板150~2000.061.061.32胶合板6000.174.57软木板3000.0931.952.511500.0581.091.89纤维板10000.348.131.896000.235.282.51石膏板10500.335.281.05纸面石膏板11000.314.731.16纤维石膏板11500.305.201.23水泥刨花板10000.347.272.017000.194.562.01木屑板2000.0651.542.10硬质PVC板14000.160铝塑复合板13800.450轻质硅酸钙板5000.116纤维增强硅酸钙板≤9500.20951~12000.251201~14000.30>14000.35岩棉板平行纤维≥1400.0400.701.22垂直纤维≥1000.0480.751.22硅酸铝棉板250~3000.0450.70复合酚醛泡沫板≥600.040二氧化硅微粉真空隔热保温板350~4500.0080.45建筑板材难燃型膨胀聚苯板18~220.0410.271.3825~350.32难燃型挤塑聚苯板25~350.0300.271.38复合硬泡聚氨酯板≥350.0240.291.38≥450.29泡沫玻璃板≤1600.052无机纤维材料岩棉、矿渣棉≤1500.044玻璃棉板、毡400.0370.521.06膨胀珍珠岩制品水泥膨胀珍珠岩4000.162.491.176000.213.441.178000.264.371.17沥青、乳化沥青膨胀珍珠岩3000.0931.771.554000.122.281.55木材橡木、枫树热流方向垂直木纹7000.174.902.51热流方向顺木纹7000.356.932.51松、木、云杉热流方向垂直木纹5000.143.852.51热流方向顺木纹5000.295.552.51其他材料夯实粘土20001.1612.991.0118000.9311.031.01加草粘土16000.769.371.0114000.587.691.01轻质粘土12000.476.361.01花岗石、玄武岩28003.4925.490.92大理石28002.9123.270.92砾石、石灰岩、砂岩24002.0418.030.92SBS改性沥青防水卷材9000.239.371.62APP改性沥青防水卷材10500.239.371.62合成高分子防水卷材5800.156.071.14油毡纸6000.173.331.47石油沥青14000.276.731.6810500.174.711.68紫铜85004073240.42青铜800064.01180.38建筑钢材785058.21260.48铝27002031910.92铸铁725049.91120.48玻璃钢18000.529.251.26建筑隔墙用轻质条板(板厚≥120mm)面密度(kg/m2)传热系数(W/㎡·K)≤110≤2.0附件2常用建筑材料热物理性能计算参数取值膨胀聚苯板(EPS板) 0.038~0.041挤塑聚苯板(XPS板) 0.028~0.03岩棉板0.041~0.045胶粉聚苯颗粒保温浆料 0.057~0.06聚氨酯发泡材料 0.025~0.028珍珠岩等浆料 0.07~0.09附件3常用建筑材料热物理性能计算参数取值《全国民用建筑工程设计技术措施/暖通空调.动力》(2009年版)附件4常用建筑材料导热系数的修正系数取值序号材料名称使用范围修正系数1难燃型膨胀聚苯板用于外墙、架空楼板1.20用于屋面1.252复合硬泡聚氨酯板用于外墙、架空楼板1.10用于屋面1.153蒸压加气混凝土砌块用于墙体1.25用于屋面1.504无机保温砂浆用于外墙、分户楼板1.305复合酚醛泡沫板用于外墙、架空楼板1.156难燃型挤塑聚苯板用于外墙、架空楼板1.15用于屋面1.207现浇泡沫混凝土用于分户楼板1.20用于屋面1.508胶粉聚苯颗粒保温浆料用于外墙1.309烧结陶粒混凝土用于屋面1.5010全轻混凝土用于分户楼板、地面1.2011二氧化硅微粉真空隔热保温板用于外墙、架空楼地面1.40用于屋面1.6012硅酸铝棉板用于外墙1.30用于屋面1.5013岩棉板用于外墙1.3014泡沫玻璃板用于外墙1.20实例1 华铜搬迁小区 住宅建筑围护结构热工性能判定表3.1-2 建筑物屋面传热系数每层材料名称厚度mm导热系数w/(m.k)修正系数热阻值m2.k/w砂浆找平层200.9310.022 SBS高聚物改性沥青防水卷材30.2310.013 水泥砂浆找平层200.9310.022 EPS保温板1000.0411.22.927 钢筋混凝土1201.7310.069 水泥砂浆找平层200.9310.022 屋面各层之和 3.074 屋面热阻R0=Ri+∑R+Re=3.232 屋面传热系数K=1/R0=0.309 表3.1-3 建筑物外墙主断面传热系数每层材料名称厚度mm导热系数w/(m.k)修正系数热阻值m2.k/w聚合物水泥砂浆50.9310.005 硬泡聚氨酯喷涂400.0251.11.760 EPS胶粉聚苯颗粒浆料150.061.250.313 水泥砂浆200.9310.022 轻集料混凝土小型空心砌块2400.5310.453 水泥砂浆200.9310.022 外墙各层之和 2.574 外墙热阻R0=Ri+∑R+Re=2.732 外墙传热系数K=1/R0=0.366 表3.1-4 建筑分隔采暖与非采暖空间的隔墙传热系数表每层材料名称厚度mm导热系数w/(m.k)修正系数热阻值m2.k/w水泥砂浆200.9310.。