    • 双活数据中心方案对比 V1NetApp MetroClusterEMC vplexIBM SVC尤贵冲Guichong_you@.hk201306 NetApp MetroCluster原理简述一套HA设备,利用光纤或交换机把控制器距离拉远利用syncmirror实现aggr级别的数据镜像,镜像物理分离Software:  syncmirror_local license同步镜像aggr cluster license 接管故障控制器 cluster_remote license 接管整个故障节点 NetApp MetroCluster保护级别 Stretch MetroClusterNode 1Node 2500mData Center Stretch MetroCluster™Aggregate XAggregate YAggregate Y MirrorAggregate X Mirror4NetApp Confidential - Limited Use Fibric MetroClusterBuildingABuildingBNo SPOFs – redundancy in all components and connectivityDedicated pairs of FC switchesDark Fiber<=160 kmFabric MetroCluster™NetApp Confidential - Limited UseAggregate XAggregate Y MirrorAggregate YAggregate X MirrorDWDMDWDM5 软件免费Software:  syncmirror_local license同步镜像aggr cluster license 接管故障控制器 cluster_remote license 接管整个故障节点 FibreBridge 6500N (1 of 4)•使SAS接口的shelf支持MetroCluster•协议转换 from SAS to FC•Requires DOT 8.1•每个shelf Stack 2个 (冗余)7NetApp Confidential - Internal Use Only FibreBridge 6500N (2 of 4) 8NetApp Confidential - Internal Use Only¡2 FibreBridges per Stack of SAS Shelves •One to IOM A, Other to IOM B (multipath HA)¡4 FibreBridges Minimum per MetroCluster FibreBridge 6500N (3 of 4) : 端口9NetApp Confidential - Internal Use Only¡2 8Gb Fibre Channel SFP+ ports¡2 x4 6Gb SAS QSFP+ ports (only 1 port used)¡2 Ethernet ports for management¡1 Serial port for initial configuration FibreBridge 6500N (4 of 4): Stack10NetApp Confidential - Internal Use Only•每个FibreBridge 最多10个shelf•Shelf 混插SAS DisksSATA DisksDS4243YESYES, BSASDS2246YESN/ADS4243 (SAS disks)DS4243(SATA disks)DS2246DS4243 (SAS disks)SAMEYESNODS4243 (SATA disks)YESSAMENODS2246NONOSAME FibreBridge Stretch MetroCluster11NetApp Confidential - Internal Use Only¡Each Controller connects to Every FibreBridge ¡SAS shelves (via bridge) can be added to existing DS14 Stretch MetroCluster FibreBridge Fabric MetroCluster¡FibreBridge connects to only 1 Switch (point-to-point mode). ¡SAS shelves (via bridge) can be added to existing DS14FC Fabric MetroCluster¡Spindle limit: 840 applies to DS14FC. Total (DS14 + SAS) should not exceed platform limit MetroCluster 方案优势•一次性设置--简单•零切换管理•零计划及计划外停机•读性能提高80%•比友商的成本和复杂度低50%MetroCluster MetroCluster 提供的连续可用性解决方案比友商的成本和复杂度低提供的连续可用性解决方案比友商的成本和复杂度低50%50%MetroCluster与应用集成可以构建在单一数据中心或跨园区建设 MetroCluster方案优势•重复数据删除技术帮助MetroCluster解决方案节省成本•重复数据删除技术在源和镜像存储系统都帮助节省成本–通过V系列的虚拟化技术也可以为其他厂家的存储系统提供投资保护和实现高效存储•客户可量化的容量节省*:–平均节省25-30%–虚拟化环境节省50-90%*基于NetApp AutoSupport数据 MetroCluster方案优势Disaster Recovery SiteNetApp Confidential - Limited Use深圳南京本地高可用和远程容灾的完美结合 MetroCluster解决方案优势与vmware集成 V系列支持•V系列存储虚拟化产品,使用标准的FAS控制器和DataOntap软件,可以连接异构的SAN存储产品,获得全部的DataOntap数据管理功能,同时利旧了原有的SAN存储,保护了用户投资。

      方案劣势及规避•每个节点单控——自动切换•访问存储空间并非统一视图——多路径•V系列需要迁移数据——wafl文件系统•ATTO Bridge——其他厂商也需要其他硬件,比如vplex头或svc头 典型硬件配置 21计划停机演示FCP, ISCSI, FCoE, NFS, CIFS, HTTP, FTPABA3A3A2A1B4B3B2BPlanned Downtime Scenario1.Issue cf takeover on system022.Identity moves to 2nd controller3.I/O passes through 2nd controller4.After maintaining 1st controller, issue cf giveback5.Identity moves back to 1st controller6.Normal operations continuecf takeovercf giveback Bcf giveback控制器故障演示22FCP, ISCSI, FCoE, NFS, CIFS, HTTP, FTPAA3A3A2A1B4B3B2BController Failure Scenario1.1st Controller fails2.Identity moves to 2nd controller3.I/O passes through 2nd controller4.After repairing1st controller,issue cf giveback5.Identity moves back to 1st controller6.Normal operations continuesystem01 failed !So takeover! 23Metrocluster 磁盘柜故障演示FCP, ISCSI, FCoE, NFS, CIFS, HTTP, FTPAA‘BB‘MC Disk/Shelf Failure Scenario1.All disks failed on Site A2.Normal operation continue,data is accessed on Site B disks3.No action for users/servers required4.After bringing Site A disks online, mirrors are re-synced automatically Metrocluster 站点故障演示24FCP, ISCSI, FCoE, NFS, CIFS, HTTP, FTPAA‘BB‘MC Site Failure Scenario1.Site A fails2.2nd controller checks heartbeat, disk-connections and IP connection while still serving it‘s data3.Human or process on 3rd Site identifies site-failure4.Issue cf takeover –d5.Identity moves to second controllerSiteA down orsite-connection broken?cf takeover -dMC Site Failure Scenario (cont.)6.VMWare-HA brings datastores back online and starts the VMs7.After bringing Site A back online, issue cf giveback8.Identity moves back to 1st controller9.Resync aggregates10.VMotion VMs back to Site Acf giveback EMC VPLEX产品介绍 EMC VPLEX Metro原理简述每个节点存储设备之上再另加一个或多个VPLEX引擎,组成集群。

      集群利用 AccessAnywhere 支持跨远距离共享、访问和移置单个数据拷贝提供同步距离内两个 VPLEX 群集之间的数据访问和移动Vplex引擎间通过fc或IP网络同步数据 EMC VPLEX Metro功能 Vplex metro 典型组网 Vplex metro 典型组网 VPLEX 群集配置选项单引擎单引擎两个控制器32 个光纤通道端口64 GB 缓存双引擎双引擎四个控制器64 个光纤通道端口128 GB 缓存四引擎四引擎八个控制器128 个光纤通道端口256 GB 缓存从小配置开始,透明地扩展引擎从小配置开始,透明地扩展引擎引擎电源管理服务器引擎电源引擎电源8 端口光纤通道交换机8 端口光纤通道交换机交换机电源交换机电源管理服务器引擎电源8 端口光纤通道交换机8 端口光纤通道交换机引擎电源引擎电源引擎电源交换机电源交换机电源管理服务器 VPLEX 硬件配置 VPLEX Metro Ÿ最多 8 个虚拟化引擎Ÿ总计 16,000 个虚拟化 LUNŸ在数据中心内或跨数据中心Ÿ支持同步距离对主机群集的支持对主机群集的支持ESX 群集之间的远距离 Vmotion(100 公里)具有 Hyper-V 功能的 MSCS/CSV(100 公里)*群集文件系统* 引擎电源引擎电源8 端口光纤通道交换机8 端口光纤通道交换机交换机电源交换机电源管理服务器引擎电源引擎电源引擎电源引擎电源8 端口光纤通道交换机8 端口光纤通道交换机交换机电源交换机电源管理服务器引擎电源引擎电源AccessAnywhere* 请参考 Powerlink 上的 E-Lab 文档“EMC VPLEX 简单支持列表” VPLEX 引擎互联 VPLEX 性能 缓存目录缓存目录 H缓存目录缓存目录 G缓存目录缓存目录 B缓存目录缓存目录 A分布式缓存吻合性基于目录的分布式缓存吻合性可跨所有引擎高效地维护缓存状态一致性缓存缓存缓存缓存引擎缓存吻合性目录引擎缓存吻合性目录块地址块地址12345678910111213…缓存缓存 A缓存缓存 C缓存缓存 E缓存缓存 G引擎缓存吻合性目录引擎缓存吻合性目录块地址块地址12345678910111213…缓存缓存 A缓存缓存 C缓存缓存 E缓存缓存 G缓存目录缓存目录 D缓存目录缓存目录 C缓存目录缓存目录 F缓存目录缓存目录 E 新写入:新写入: 块块 3读取读取 块块 3 VPLEX与异构阵列数据就地迁移(不拷贝数据)数据就地迁移(不拷贝数据)Ÿ连接到VPLEXŸ把卷导入 VPLEX(1:1 映射)Ÿ从阵列卸载卷Ÿ从VPLEX呈现卷给主机Ÿ重新挂载卷阵列列主机主机VPLEX最小最小 中断中断 Vplex劣势•结构复杂、建设周期长、安装配置任务繁多•引入单独的管理GUI•不支持NAS•增加运营成本:array->vplex->host•不支持存储效率:去重、精简配置、快照等•不支持存储分层 IBM SVC原理简述和EMC VPLEX类似,每个节点存储设备之上再另加一个或多个SVC节点,组成集群。

      SVC可用于管理最多由8个节点(或集群服务器)构成的存储环境集群内的SVC节点以成对的形式划分为组,称为I/O组每一对节点负责一个给定的虚拟磁盘或vDisk的数据输入/输出服务一个SVC簇中的每一个节点都被划分在某一个I/O组内,并且从设计上规定,每个I/O只能拥有两个节点集群利用 MetroMirror创建数据拷贝 IBM SVC特点支持虚拟化异构存储,不用迁移数据支持全线异构存储和免费的精简规划和EasyTier IBM SVC硬件 SVC 2145-8G4 引擎参数•New SVC engine–Two dual-core Intel Xeon 5160 processors at 2.33GHz–8GB of cache–Four 4Gbps FC ports–SVC code improvements to use multi-core processor IBM SVC兼容性 IBM SVC典型组网 。