4系列尺寸氯气传感器Cl2-M-20原装进口.pdf
2页ELECTROCHEMICAL GAS SENSORS SPECIFICATION SHEET FOR Cl2 Sensor TYPE Cl2/M-20PERFORMANCE CHARACTERISTICSCROSS-SENSITIVITY DATAInterfering Gas Concentration ReadingBr2 10 ppm 2.5 ppmCO 300 ppm 0 ppmSO2 5 ppm 0 ppmNO 35 ppm 0 ppmH2 300 ppm 0 ppmNO2 20 ppm ~ 20 ppmH2S NDPerformance data conditions: 20 °C, 50% RH and 1013 mbarAPPLICATIONSContinuous Air Quality MonitoringSafety and Environmental ControlFor Portable Gas DetectorsPHYSICAL CHARACTERISTICSBOTTOM VIEWMiniature-Size Outline DimensionsReferenceSensingCounter13.5 mmPCD18 mm90°SIDE VIEW20 mm5 mmPin Projection 1.5 mm Pinson 13.5 mm PCD REV.: 11/2012 Page 1 of 2Nominal Range 0 – 20 ppmMaximum Overload 200 ppmExpected Operation Life 2 years in airOutput Signal - 600 ± 150 nA/ppm Resolution 0,1 ppmTemperature Range - 20 °C to 45 °CPressure Range Atmospheric ± 10%Pressure Coefficient No data T80 Response Time < 30 sec Relative Humidity Range 15 % to 90 % R.H. non-condensingTypical Baseline Range (pure air, 20°C)< 0,2 ppmMaximum Zero Shift (+20°C to +40°C)- 0,4 ppmLong Term Output Drift < 2% signal loss/monthRecommended Load Resistor 10 – 33 OhmBias Voltage Not requiredRepeatability < 2 % of signalOutput Linearity LinearWeight ~ 5.4 gPosition Sensitivity NoneStorage Life Six months in containerRecommended Storage Temperature5 °C – 20 °CWarranty Period 12 months from date of dispatch深圳市深国安电子科技有限公司地址:广东省深圳市龙华新区牛栏前大厦C507 :86 755-85258900 网址: ELECTROCHEMICAL GAS SENSORS SPECIFICATION SHEET FOR Cl2 Sensor TYPE Cl2/M-20TEMPERATURE DEPENDENCEThe output of an electrochemical sensor varies with temperature. The graphs below show the variation in output with temperature for this type of sensor. The results are shown in the graphs as a mean for a batch of sensors, along with confidence intervals corresponding to ±3 times the standard deviation. The sensitivity dependence is expressed as a percentage of the signal at 20 °C. The baseline is virtually not affected by changes in temperature.The data contained in this document is for guidance only. Membrapor AG accepts no liability for any consequential losses, injury or damage resulting from the use of this document or the information contained within it. The data is given for guidance only. Customers should test under their own conditions, to ensure that the sensors are suitable for their own requirements.REV.: 11/2012 Page 2 of 2Sensitivity Temperature Dependence50%60%70%80%90%100%110%-20 -10 0 10 20 30 40Temperature (°C)Output(referenced to 20 °C)Mean+3SD-3SD深圳市深国安电子科技有限公司地址:广东省深圳市龙华新区牛栏前大厦C507 :86 755-85258900 网址: 。