型式试验报告模板-第4篇.docx
18页型式试验报告模板 1.试验项目及结论Order Test Type Testing Date Test Results 1 Conducted Emission Test 11.29 PASS2 Immunity to Continuous ConductedInterference Test11.29 PASS3 Radiated Emission Test(30MHz ~ 1000MHz)11.29 PASS4 Immunity To Radiated Electric Fields Test 11.29 PASS5 Electrical Fast Transient/Burst Immunity Test11.29 PASS6 Surge Immunity Test 11.29 PASS7 Voltage Dips, Short Interruptions and VoltageVariations Immunity Test11.30 PASS8 Voltage fluctuation and Flicker Test 11.30 PASS9 Harmonic Current Emissions Test 11.30 PASS10 Electrostatic Discharge Immunity Test 11.30 PASS 2. Mode of operation during the testConducted Emission Test:Mode1:Norma l Operation(DC 48V)Mode2: Norma l Operation(AC 220V/50Hz)Immunity to Continuous Conducted Interference Test:Mode1:Norma l Operatio nRadiated Emission Test(30MHz ~ 1000MHz):Mode1: Normal OperationImmunity To Radiated Electric Fields Test:Mode1:Norma l Operation(DC 48V)Mode2: Norma l Operation(AC 220V/50Hz)Electrical Fast Transient/Burst Immunity Test:Mode1:Normal Operation(DC 48V)Mode2: Normal Operation(AC 220V/50Hz)Mode2: Normal Operation(AC 220V/50Hz)Voltage Dips, Short Interruptions and Voltage Variations Immunity Test: Mode1:Normal Operation(DC 48V)Mode2: Normal Operation(AC 220V/50Hz)Voltage fluctuation and Flicker Test:Mode1:Normal Operation(DC 48V)Mode2: Normal Operation(AC 220V/50Hz)Harmonic Current Emissions Test:Mode1:Normal Operation(DC 48V)Mode2: Normal Operation(AC 220V/50Hz)Electrostatic Discharge Immunity Test:Mode1:Normal Operation1. Conducted Emission Test1.1. Conducted Emission Test Data and ResultsTes t Mod e : Mod e 1: Norma l Operation(D C 48V)DC Power : DC 48V Phase : LINE Temperature : 23°C Humidity : 52% Pressure(mbar) : 1002 Date: 2014/11/29No. Frequenc y(MHz) Facto r(dB)Readin g(dBuV)Leve l(dBuV)Limi t(dBuV)Margi n (dB)Detector1 0.1580 10.19 31.79 41.98 65.56 -23.58 QP2 0.1580 10.19 13.69 23.88 55.56 -31.68 AVG3 0.4460 10.27 29.01 39.28 56.95 -17.67 QP4 0.4460 10.27 22.69 32.96 46.95 -13.99 AVG5 1.0820 10.33 21.25 31.58 56.00 -24.42 QP6 1.0820 10.33 14.59 24.92 46.00 -21.08 AVG7 7.9860 10.54 20.34 30.88 60.00 -29.12 QP8 7.9860 10.54 19.57 30.11 50.00 -19.89 AVG9 15.9740 10.67 17.82 28.49 60.00 -31.51 QP10 15.9740 10.67 14.68 25.35 50.00 -24.65 AVG11 29.9300 10.84 17.79 28.63 60.00 -31.37 QP12 29.9300 10.84 16.09 26.93 50.00 -23.07 AVG Note: Measuremen t Leve l = Readin g Leve l + Correc t Facto rTes t Mod e : Mod e 1: Norma l Operation(D C 48V)DC Power : DC 48V Phase : NEUTRALTemperature : 23°C Humidity : 52%Pressure(mbar) : 1002 Date: 2014/11/29No. Frequenc y(MHz) Facto r(dB)Readin g(dBuV)Leve l(dBuV)Limi t(dBuV)Margi n(dB)Detector1 0.1539 9.86 31.22 41.08 65.78 -24.70 QP2 0.1539 9.86 13.69 23.55 55.78 -32.23 AVG3 0.4420 9.87 28.05 37.92 57.02 -19.10 QP4 0.4420 9.87 21.34 31.21 47.02 -15.81 AVG5 1.0980 9.90 21.36 31.26 56.00 -24.74 QP6 1.0980 9.90 13.40 23.30 46.00 -22.70 AVG7 7.9860 10.09 20.59 30.68 60.00 -29.32 QP8 7.9860 10.09 19.79 29.88 50.00 -20.12 AVG9 15.9780 10.18 12.82 23.00 60.00 -37.00 QP10 15.9780 10.18 7.32 17.50 50.00 -32.50 AVG11 29.4580 10.31 20.36 30.67 60.00 -29.33 QP12 29.4580 10.31 18.16 28.47 50.00 -21.53 AVG Note: Measuremen t Leve l = Readin g Leve l + Correc t Facto rTes t Mod e : Mod e 2: Norma l Operation(A C 220V/50Hz)DC Power : AC 220V/50Hz Phase : LINETemperature : 23°C Humidity : 52% Pressure(mbar) : 1002 Date: 2014/11/29No. Frequenc y(MHz) Facto r(dB)Readin g(dBuV)Leve l(dBuV)Limi t(dBuV)Margi n (dB)Detector1 0.1500 10.13 33.31 43.44 65.99 -22.55 QP2 0.1500 10.13 20.60 30.73 55.99 -25.26 AVG3 1.1180 10.16 23.34 33.50 56.00 -22.50 QP4 1.1180 10.16 16.56 26.72 46.00 -19.28 AVG5 1.5220 10.17 21.37 31.54 56.00 -24.46 QP6 1.5220 10.17 14.94 25.11 46.00 -20.89 AVG7 7.9900 10.25 15.67 25.92 60.00 -34.08 QP8 7.9900 10.25 12.28 22.53 50.00 -27.47 AVG9 15.9780 10.49 14.42 24.91 60.00 -35.09 QP10 15.9780 10.49 8.36 18.85 50.00 -31.15 AVG11 23.9580 10.41 22.71 33.12 60.00 -26.88 QP12 23.9580 10.41 21.01 31.42 50.00 -18.58 AVG Note: Measuremen t Leve l = Readin g Leve l + Correc t Facto rTes t Mod e : Mod e 2: Norma l Operation(A C 220V/50Hz)DC Power : AC 220V/50Hz Phase : NEUTRAL Temperature : 23°C Humidity : 52% Pressure(mbar) : 1002 Date: 2014/11/29No. Frequenc y(MHz) Facto r(dB)Readin g(dBuV)Leve l(dBuV)Limi t(dBuV)Margi n(dB)Detector1 0.1500 10.13 32.58 42.71 65.99 -23.28 QP2 0.1500 10.13 19.63 29.76 55.99 -26.23 AVG3 1.1420 10.18 24.80 34.98 56.00 -21.02 QP4 1.1420 10.18 17.43 27.61 46.00 -18.39 AVG5 7.9860 10.26 17.78 28.04 60.00 -31.96 QP6 7.9860 10.26 15.55 25.81 50.00 -24.19 AVG7 15.9780 10.51 16.77 27.28 60.00 -32.72 QP8 15.9780 10.51 13.07 23.58 50.00 -26.42 AVG9 23.9660 10.36 21.20 31.56 。