好文档就是一把金锄头!
欢迎来到金锄头文库![会员中心]
电子文档交易市场
安卓APP | ios版本
电子文档交易市场
安卓APP | ios版本

OTIS-SKY安装参数.pdf

37页
  • 卖家[上传人]:飞***
  • 文档编号:53103453
  • 上传时间:2018-08-28
  • 文档格式:PDF
  • 文档大小:661.94KB
  • / 37 举报 版权申诉 马上下载
  • 文本预览
  • 下载提示
  • 常见问题
    • OTIS Engineering Center BerlinSoftware Basic Data MCS - TCBCList of Installation Parameters No.: GAA30781AAG_INSSCN: GAA30781AAGPage: 1 / 1 Date: 2007-Jun-25 MCS - TCBC List of Installation Parameters(TCBC或GECB板安装参 数解释)Running on PCB: GAA26800KA or higher (TCBC) Software Version: GAA 30781 AAG Document Revision : V 1.0 Date SCN Author Comment 07-Sep-2004 GAA 30781 AAA M. Hoinkis original document based on TCBC/HCB software GAA 30081 AAF 14-Dec-2004 GAA 30781 AAB M. Hoinkis corrections and EFS-RC extended. 12-May-2005 GAA 30781 AAC M. Hoinkis Px2.1, SPB-TYP, ACG, HWY-TYP added 23-Jun-2005 G13 30781 AAD M. Hoinkis HWY-TYP modified 05-Jan-2006 GAA 30781 AAE M. Hoinkis EQO / EFO-SD update; DCB-TYP / PI- POS added; 26-Apr-2006 GAA 30781 AAF M. Hoinkis SHO-LT corr. 25-Jun-2007 GAA 30781 AAG M. Hoinkis DW-DLY, TLD-DW-D, DO/DC added; EFSOPD corr. OTIS Engineering Center BerlinSoftware Basic Data MCS - TCBCList of Installation Parameters No.: GAA30781AAG_INSSCN: GAA30781AAGPage: 2 / 2 Date: 2007-Jun-25 Copyright 2013, OTIS GmbH 快车下抱闸打开的最大持续时间OTIS Engineering Center BerlinSoftware Basic Data MCS - TCBCList of Installation Parameters No.: GAA30781AAG_INSSCN: GAA30781AAGPage: 19 / 19 Date: 2007-Jun-25 5 – DOORS 门(SVT M-1-3-1-5-GO ON)No. Symbol Default Purpose and Range since 0.DOOR 门的类型11 Type of Doors: 11 GENERIC (DO/DC) 12 DCSS-5 DOB直接进入门机里 13 DCSS-5, AT120 with DOBF (direct DOB) DOB 进入门机但有另一个信号Note: DOOR=12 requires that also REAR=12 is selected AAG AAA AAA 1.REAR 后门11 Type of Doors: 11 GENERIC (DO/DC) 12 DCSS-5 13 DCSS-5, AT120 with DOBF (direct DOB) Note: REAR=12 requires that also DOOR=12 is selected AAG AAA AAA 2.EN-DDO 0 Enable DDO (double door operation): Select that both front and rear door will open simultaneously 允许取消开门(前后门操作)0 Disabled 禁止 1 double door on car call and on hall call前后 门的内选和外呼均不响应 2 double door on car call, selected door on hall call 前后门的内选不响应,指定的门那一 侧响应外呼3.EN-ADM 0 Alternating Door Mode交互门模式 0 doors can open simultanously 1 ADM preference to front door 2 ADM preference to rear door4.F:DO-TYP 0 type of DO handling开门 DO 类型 00 DO never pulled DO从不吸合 01 DO pulled when car door fully opened当门全 开时 DC 吸合 10 DO pulled during opening当门开时DC 吸合 11 DO pulled when car door opening and also when fully opened当门开至门全开DC 均吸 合note: only applicable for GENERIC door operator仅在门类 型设置为11 时有效AAG 5.F:DC-TYP 0 type of DC handling关门 DC 类型 00 DC never pulled 01 DC pulled when car door fully closed 10 DC pulled during closing 11 DC pulled when car door closing and also when fully closed note: only applicable for GENERIC door operator AAG OTIS Engineering Center BerlinSoftware Basic Data MCS - TCBCList of Installation Parameters No.: GAA30781AAG_INSSCN: GAA30781AAGPage: 20 / 20 Date: 2007-Jun-25 5 – DOORS 门(SVT M-1-3-1-5-GO ON)No. Symbol Default Purpose and Range since 6.F:EN-ACG厅门 信号0 enable DW input for ACG (front):ACGY下允许 DW 输入0 自动门automatic front hoistway doors 1 手动门manual front hoistway doorsAAC 7.F:EN-DCL 0 enable DCL input at IO 694设置 IO694 允许 DCL 输入 0 no DCL switch无 DCL 开关1 DCL at IO no. 694 设置 I/O694 的 DCL note : only applicable for GENERIC door operator. AAG 8.R:DO-TYP 0 type of RDO handling 00 RDO never pulled 01 RDO pulled when car door fully opened 10 RDO pulled during opening 11 RDO pulled when car door opening and also when fully opened note: only applicable for GENERIC door operator AAG 9.R:DC-TYP 0 type of RDC handling 00 RDC never pulled 01 RDC pulled when car door fully closed 10 RDC pulled during closing 11 RDC pulled when car door closing and also when fully closed note : only applicable for GENERIC door operator AAG 10.R:EN-ACG 0 enable DW input for ACG (rear): 0 automatic rear hoistway doors 1 manual rear hoistway doorsAAC 11.R:EN-DCL 0 enable RDCL input at IO 695 0 no RDCL switch 1 RDCL at IO no. 695 note: only applicable for GENERIC door operator AAG 12.CM-PROT 0 max. ON-time of CMR when car stops in ERO When cam is dropped, it is not possible to detect UIB or DIB because the safety chain is opened by DS. Therefore the CM must be energized during ERO. This parameter gives the duration after which the CMR is dropped to protect the cam from burning.检修时最大CMR 保持时间0 CMR not pulled不吸合 1 (1) 254 [10 s] CMR drops after specified time (CMR pulls again when moving or switched to NOR) 255 no protection: CMR is always pulled during ERO (100% ED required)AAC OTIS Engineering Center BerlinSoftware Basic Data MCS - TCBCList of Installation Parameters No.: GAA30781AAG_INSSCN: GAA30781AAGPage: 21 / 21 Date: 2007-Jun-25 5 – DOORS 门(SVT M-1-3-1-5-GO ON)No. Symbol Default Purpose and Range since 13.LDR 重开门模 式0 Limited Door Reversal: 0 Full DOB, full EDP, full LRD三种情况下门全 开 1 Full DOB, limited EDP, full LRD 14.EN-PMO 0 Enable PMO (door time monitoring): 允许门时间监控 If the actual door time is longer than 2 seconds and the LRD input is operated, door time will be decreased to 2 seconds. If the door time already is less than 2 seconds i。

      点击阅读更多内容
      关于金锄头网 - 版权申诉 - 免责声明 - 诚邀英才 - 联系我们
      手机版 | 川公网安备 51140202000112号 | 经营许可证(蜀ICP备13022795号)
      ©2008-2016 by Sichuan Goldhoe Inc. All Rights Reserved.