煤矿用电缆-选型号样本.pdf
18页煤矿用电缆 Cable for Coal Mine Application煤矿用额定电压8.7/10kV及以下交联绝缘阻燃电力电缆 Flame Retardant Power Cable with Cross linked Insulation, Rated Voltage of 8.7/10kv or Lower for Coal Mine Application 煤矿用额定电压3.6/6kV及以下聚氯乙烯绝缘阻燃电力电缆 Flame Retardant Power Cable with PVC Insulation, Rated Voltage of 3.6/6kV or Lower for Coal Mine Application 煤矿用额定电压0.66/1.14kV及以下移动类阻燃软电缆 Mobile Flame Retardant Flexible Cable with rated voltage of 0.66/1.14kV or lower for Coal Mine Application煤矿用电缆煤矿用额定电压8.7/10kV及以下交联绝缘阻燃电力电缆 Cross Linked Insulation Flame Retardant Power Cable of Rated Voltage 8.7/10kV or Lower for Coal Mine Application一、 生产执行标准 Executive standard: 二、 工作条件Working Condition1、 电缆导体的允许最高工作温度为90℃。
2、 短路时 (最长持续时间不超过5秒) 电缆导体的最高温 度不超过250℃ 3、 电缆敷设温度不低于0℃Max. working temperature of cable conductor is 90℃. Max. temperature of cable conductor is no more than 250℃ during shirt circuit. (The longest lasting time is no more than 5 seconds.) Cable installation temperature is no less than 0℃.三、 电缆型号名称cable type Insulated resistance of rubber insulation power core shall meet the requirements stipulated in the following table.动力线芯标称截面(mm2)Nominal cross section area of power core20℃时绝缘电阻(MΩ.km) Insulated resistance at 20℃ 动力线芯标称截面(mm2)Nominal cross section area of power core20℃时绝缘电阻(MΩ.km) Insulated resistance at 20℃4≥20095≥806≥180120≥5010≥16015016≥12018525≥12024035≥10030050≥10040070≥80/3、 工频电压试验 电缆的绝缘动力线芯应经受下表规定的工频电压试验而 不被击穿:A.C. voltage test Insulated power core of cable shall endure following A.C. voltage test without puncture.额定电压U0/U(kV) rated voltage试验电压(有效值)(kV)Test voltage (effective value)施加电压时间(min)Time for giving pressure 0.38/0.663.0 5 0.66/1.143.74、 成品电缆阻燃性能均应满足MT386标准中各项试验 要求。
Flame retardant performance of finished cable can meet all kinds of test requirements stipulated in MT386 standard.七、 电缆结构图The figure of cable structure123456ANHUI TIANKANG(GROUP)SHARES CO.,LTD.113MYP-0.38/0.66 MYPE-0.38/0.66 MY-0.38/0.66 MYP-0.66/1.14 MYPE-0.66/1.14 MYE-0.38/0.661-动力线芯导体; 2-绝缘; 3-填充; 4-绝缘屏蔽; 5-地线芯导 体; 6-外护套1. Power core conductor 2. Insulation 3. Filler 4. Insu- lated shielding 5. earthing conductor 6. Outer sheath八、 电缆标志Cable mark1、 绝缘线芯识别标志: 采用颜色或表面印阿拉伯数字,当采用颜色时, 单芯电缆绝缘为红色或白色; 4芯电缆动力线 芯为红色、 白色、 浅蓝色, 地线芯为黑色。
当采用阿拉伯数字 编码时, 4芯电缆动力线芯为1、 2、 3, 地线芯为0 2、 电缆识别标志: 井下用不同电压等级电缆的护套宜采 用不同的识别颜色, 见下表:Identified mark of insulated core: using color OR printing numbers on the surface of insulated core. If you use color to identify, the insulated color of single core cable is red or white. Power core color of c able with 4 cores is red, white, light blue and black for earthing conductor. If you print numbers on the surface of insulated core, power core of cable with 4 cores is 1, 2, 3 and 0 for earth- ing conductor.Identified mark of cable: Different cable sheath color will be used to identify cable under well with different voltage degree. Please see the following table.U0/U(kV)3.6/61.9/3.30.66/1.140.38/0.66及以下 0.38/0.66 or lower护套颜色 Sheath color红 red黑 black黄 Yellow黑 black成品电缆护套表面至少应明显印有: 制造厂名、 型号规 格、 电压、 煤安标志的内容。
Manufacturer, type, voltage and coal mine safety mark etc. will be clearly printed on the surface of finished cable sheath九、 交货长度delivery length1、 电缆根据双方的协议长度交货 2、 无协议时, 按产品标准规定: 最小短段长度为40米,短段长度应不超过总长度的10% 3、 长度计量误差不超过±0.5%Delivery length of cable depends on final both agree- ments. If there is no final agreement, the cable no shorter than 40 meters is allowed for delivery, which accounts for no more than 10% of the total length. Length error of cable is no more than ±0.5%.114。