酒店管理会所 希尔顿酒店设计标准第18节食品饮料储藏室.doc
7页第18节食品饮料储藏室18-1.00 GENERAL18-1.00 总则18-1.01 Al I food and beverage del iver ies are checked and weighed at the receivingarea by the receiving clerk before they are moved tothe food and beveragestorerooms. Food and beverage items are kept either onsteeI shelving in openracks, in boxes in the screened-in buIk storage area orin cold storage in therefr i gerators or freezers.所有食品和饮料在转到食品饮料储藏室之前,均应由收货员在收货区检查并称重食品和饮料保存在开架的钢制货架、带筛眼大型储藏区中的箱子或者冰箱或冷库中的冷藏储藏区中18~1.02 Food and beverage storage must be laid out by the kitchen pIanningconsultants and approved by H i I ton HoteIs Corporat i on.食品和饮料储存方案必须由厨房规划顾问设计并由希尔顿酒店集团批准。
18~1.03 Food and beverage storerooms must have a minimum cI ear ceiling he i ghtof 9 —0 || (2. 7m).食品饮料储藏室天花板净高至少应为2.7米18-1.04 Food storage areas must be centra I ly located between the receiving areaand the preparat ion area, but separate from the chef s coolers and banquet preparea.食品储藏区必须位于收货区和取菜区之间的中间,但与厨房冷库和宴会取菜区分开18-1.05 Liquor and wines are kept i n a separate Iocked storeroom with a coo Iarea for wi ne storage.白酒和葡萄酒保存在单独的上锁储藏室中,储藏室设有供储藏葡萄酒的冷藏区18~1.06 Liquor storage areas should be located adjacent to the pr imary serviceci rculation and reasonabIe proximate to the receiving area. Convenient access to I i quor storage must be avai I able from the banquet service corr i dor, the lounge and the kitchen service bar.酒类储藏区应位于主服务流通区附近,并应相当靠近收货区。
必须可从宴会服务走廊、 酒廊和厨房服务吧方便地进入酒类储藏区18~1.07 The beverage d i spens i ng equipment room should be centra I Iy located to the requi red dispensing points.饮料配给设备室应位于所需配给点的中央18~1.08 Bu I k unprepared food both dry and ref r i gerated, must be stored separately from i ssued and prepared food.大量未加工食品(包括干食品和冷冻食品)的存放必须与发放和已加工食品分开18~1.09 Provide only one lockable point of access to the I iquor storage area.Locate the walk-in refr i gerator within the storage area.为酒类储藏区只设一个入口,要求上锁将高温冷库设在该储藏区内18-1. 10 Provide modu I ar, prefabr icated walk-in ref r i gerator s and freezers with fieldinstalled, four-i nch, urethane sheet foam i nsuI at i on, vapor-proof Ii ght fixtures, exter i or thermostats and high temperature alarm system.为模块化、预组装高温冷库和低温冷库提供现场安装,并配备四英寸聚氨酯发泡保温板 材、防蒸汽灯具、外部恒温装置和高温报警系统。
18~1.11 Walk-in boxes shaI I be 8-6〃 high (2.5m). Provide an integraI buIkhead or a gyp board buIkhead from the top of the box to the underside of the ceiling or structuraI deck above.冷库箱体的高度应为2. 5米从箱体的顶部到天花板下侧或者结构底板上方采用一体化舱壁或者石膏板舱壁18-1. 12 Provide floor recess for door heaters in walk-in boxes.提供地面下沉以安装冷库箱体中的门加热器18-1. 13 Walk-in boxes shaI I be specified without prefabr icated floors. Recess and insulate bui Iding floor slab be Iow. Isolate a I I refr i gerator and freezer floor slabs from surrounding area.冷库箱体应设在无预制板楼面。
其下方为下沉和隔热楼板将所有高温冷库和低温冷库 的楼板与周围环境隔开18-1. 14 Partitions surrounding the I iquor storage area must extend and be secured to the underside of the structure above.包围酒类储藏区的隔墙必须延伸并固定到上层结构板底18-1. 15 Shelving in walk-in refr igerators should consi st of approximately 1/3 fuI I height shelving, 1/3 dunnage / slatted racks and 1/3 open area. Place fuI I he i ght she Iv i ng to rear of refr i gerator.高温冷库中的货架应包括约1/3全高度货架、1/3支撑板/板条货架和1/3开放区将 全高度货架放在冷库的后部18-2.00 DOORS, WINDOWS and HARDWARE门、窗和五金件18-2. 01 Provide a removable core lock cyl inder that i s not on the bui Iding master keying system for the entrance door to the Iiquor storage area.为通往酒类储藏区的入口门提供独立于建筑总钥匙系统的可换芯门锁。
18-2. 02 Doors on walk-in boxes sha I I have a 12〃 w x 16〃 h (300mm x 400mm) mini mum vision pane I. Do not provide reach-i n doors.冷库箱体上的门至少应配有300毫米宽x 400毫米高的观察窗不得采用延伸门18-2. 03 Entrance doors must be a minimum of 3 一6 || wide (1m) and have lockset, k i ckpI ate, and closer with hold open feature.入口门的宽度至少应为1米并有锁具、护板和保持常开的闭门器18-3.00 FINISHES 18-3.00 饰面18-3. 01 FOOD AND BEVERAGE STOREROOMS:食品饮料储藏室:Floors一 Non-skid quarry ti le, with carborundum particles地面-防滑缸砖,采用碳化硅颗粒Base 一Quarry tile (Coved base)墙踢脚-缸砖(基拱墙踢脚)Walls -・ Epoxy pa i nt / FRP墙面-环氧树脂涂料/纤维增强塑料Ceiling 一 WashabIe ceiling system / Epoxy painted gypboard天花板-可水洗天花板系统/涂有环氧树脂的石膏板18-3. 02 Provide non-skid quarry t i Ie with coved base in walk-in refr igerators and freezers.在高温冷库和低温冷库中提供防滑缸砖并采用基拱墙踢脚。
18-3. 03 WashabIe ceiling system must have an a Iuminum gr id.可水洗天花板系统必须配有铝制网格18-3. 04 Provide meta I or rubber corner guards and wa I I ra i Ii ngs at co Iumns and waI I outside corners为柱子和墙壁外角提供金属或者橡胶护角和墙壁扶手式保护板18-4.00 FF&E (NA)家具、固定装置和设备(不适用)18-5.00 SPECIAL CONSTRUCTION (Graphics and Signs) (NA)特殊结构(图形和标志)(不适用)18-6.00 MECHANICAL / PLUMBING机械/管道18-6. 01 Provide heat i ng and vent i I at ion i n storage areas.在储藏区提供供暖和通风设备18-6. 02 S i ze condens i ng un i ts and evaporator coils for walk-in boxes to operate refr i 。