    • 1、Laryngeal Mask Airway,Hai Yu Department of Anesthesiology West China Hospital Sichuan University,Introduction,The LMA was invented by Dr. Archie Brain at the London Hospital, Whitechapel in 1981 UK(1988) , US (1991) The LMA consists of two parts: The mask The tube The LMA has proven to be very effective in the management of airway crisis,Introduction continued,The LMA design: Provides an “oval seal around the laryngeal inlet” once the LMA is inserted and the cuff inflated. Once inserted, it lies

      2、 at the crossroads of the digestive and respiratory tracts.,Indications for the use of the LMA,Situations involving a difficult mask fit. May be used as a back-up device where endotracheal intubation is not successful. May be used as a “second-last-ditch” airway where a surgical airway is the only remaining option.,Contraindications of the LMA,Greater than 14 to 16 weeks pregnant Patients with multiple or massive injury Massive thoracic injury Massive maxillofacial trauma Patients at risk of asp

      3、iration NOTE: Not all contraindications are absolute,Side-Effects of the LMA,Throat soreness Dryness of the throat and/or mucosa Side effects due to improper placement vary based on the nature of the placement,Equipment for LMA Insertion,Body Substance Isolation equipment Appropriate size LMA Syringe with appropriate volume for LMA cuff inflation Water soluble lubricant Ventilation equipment Stethoscope Tape or other device(s) to secure LMA,Preparation of the LMA for Insertion,Step 1: Size selec

      4、tion Step 2: Examination of the LMA Step 3: Check deflation and inflation of the cuff Step 4: Lubrication of the LMA Step 5: Position the Airway,Step 1: Size Selection,Verify that the size of the LMA is correct for the patient Recommended Size guidelines: Size 1: under 5 kg Size 1.5: 5 to 10 kg Size 2: 10 to 20 kg Size 2.5: 20 to 30 kg Size 3: 30 kg to small adult Size 4: adult Size 5: Large adult/poor seal with size 4,Step 2: Examination of the LMA,Visually inspect the LMA cuff for tears or oth

      5、er abnormalities Inspect the tube to ensure that it is free of blockage or loose particles Deflate the cuff to ensure that it will maintain a vacuum Inflate the cuff to ensure that it does not leak,TEST: VISUAL INSPECTION,Step 3: Deflation and Inflation of the LMA,Step 1: Leakage Deflate the cuff so that the cuff walls are tightly flattened against each other. Do not use the LMA airway if the cuff walls reinflate immediately and spontaneously, even if only slightly. Inflate the cuff with air fro

      6、m a complete vacuum as shown in the table below. Test Cuff Inflation Volumes: Size 1: 6 ml Size 1.5: 10 ml Size 2: 15 ml Size 2.5: 21 ml Size 3: 30 ml Size 4: 45 ml Size 5: 60 ml Size 6: 75 ml,Step 2: Herniation,Step 4: Lubrication of the LMA,Use a water soluble lubricant to lubricate the LMA Only lubricate the LMA just prior to insertion Lubricate the back of the mask thoroughly Important Notice: Avoid excessive amounts of lubricant on the anterior surface of the cuff in the bowl of the mask. I

      7、nhalation of the lubricant following placement may result in coughing or obstruction. Lubrication of the mask should avoid the use of local anesthetics in order to preserve protective reflexes against aspiration.,Step 5: Positioning of the Airway,Extend the head and flex the neck Avoid LMA fold over: Assistant pulls the lower jaw downwards. Visualize the posterior oral airway. Ensure that the LMA is not folding over in the oral cavity as it is inserted.,LMA Insertion Technique,LMA Insertion Step

      8、 1,Grasp the LMA by the tube, holding it like a pen as near as possible to the mask end. Place the tip of the LMA against the inner surface of the patients upper teeth,LMA Insertion Step 2,Under direct vision: Press the mask tip upwards against the hard palate to flatten it out. Using the index finger, keep pressing upwards as you advance the mask into the pharynx to ensure the tip remains flattened and avoids the tongue.,LMA Insertion Step 3,Keep the neck flexed and head extended: Press the mas

      9、k into the posterior pharyngeal wall using the index finger.,LMA Insertion Step 4,Continue pushing with your index finger. Guide the mask downward into position.,LMA Insertion Step 5,Grasp the tube firmly with the other hand then withdraw your index finger from the pharynx. Press gently downward with your other hand to ensure the mask is fully inserted.,LMA Insertion Step 6,Inflate the mask with the recommended volume of air. Do not over-inflate the LMA. Do not touch the LMA tube while it is being inflated unless the position is obviously unstable. Normally the mask should be allowed to rise up slightly out of the hypopharynx as it is inflated to find its correct position.,Verify Placement of the LMA,Connect the LMA to a Bag-Valve Mask device or low pressure ventilator Ventilate the patient while confirming equal breath sounds over both lungs in all fields and the absence of ventilatory sounds over the epigastrium,Securing the

      《laryngealmaskairway喉罩》由会员tia****nde分享,可在线阅读,更多相关《laryngealmaskairway喉罩》请在金锄头文库上搜索。

      点击阅读更多内容
    最新标签
    发车时刻表 长途客运 入党志愿书填写模板精品 庆祝建党101周年多体裁诗歌朗诵素材汇编10篇唯一微庆祝 智能家居系统本科论文 心得感悟 雁楠中学 20230513224122 2022 公安主题党日 部编版四年级第三单元综合性学习课件 机关事务中心2022年全面依法治区工作总结及来年工作安排 入党积极分子自我推荐 世界水日ppt 关于构建更高水平的全民健身公共服务体系的意见 空气单元分析 哈里德课件 2022年乡村振兴驻村工作计划 空气教材分析 五年级下册科学教材分析 退役军人事务局季度工作总结 集装箱房合同 2021年财务报表 2022年继续教育公需课 2022年公需课 2022年日历每月一张 名词性从句在写作中的应用 局域网技术与局域网组建 施工网格 薪资体系 运维实施方案 硫酸安全技术 柔韧训练 既有居住建筑节能改造技术规程 建筑工地疫情防控 大型工程技术风险 磷酸二氢钾 2022年小学三年级语文下册教学总结例文 少儿美术-小花 2022年环保倡议书模板六篇 2022年监理辞职报告精选 2022年畅想未来记叙文精品 企业信息化建设与管理课程实验指导书范本 草房子读后感-第1篇 小数乘整数教学PPT课件人教版五年级数学上册 2022年教师个人工作计划范本-工作计划 国学小名士经典诵读电视大赛观后感诵读经典传承美德 医疗质量管理制度 2 2022年小学体育教师学期工作总结 2022年家长会心得体会集合15篇
    关于金锄头网 - 版权申诉 - 免责声明 - 诚邀英才 - 联系我们
    手机版 | 川公网安备 51140202000112号 | 经营许可证(蜀ICP备13022795号)
    ©2008-2016 by Sichuan Goldhoe Inc. All Rights Reserved.