温室大棚基础计算书
结构设计说明1. 本工程主体结构设计使用年限为30年2. 基本风压为0.56KN/,地面粗糙度类别C,结构重要性系数取1.0,基本风压重现期为30年,基本雪压为0.3KN/,温室加热影响系数取0.6。3. 种植作物可变荷载150N/,安装检修活荷载100N/4. 设备均布恒荷载70N/(含移动喷灌机,环流风机,遮阳保温系统,作物吊挂系统,加温主管),温室主体均布恒荷载20N/。5. 结构设计按照由可变荷载效应控制的基本组合进行验算。独立柱基础计算书一、基础类型及计算形式基础类型:阶梯柱基计算形式:验算截面尺寸二、依据规范建筑地基基础设计规范(GB 50007-2011)混凝土结构设计规范(GB 50010-2010)三、几何数据及材料特性几何数据:B1 = 400mm, W1 = 400mm,H1 = 200mm,B = 300mm, H = 300mm基础沿x方向的长度l = 2B1 = 0.80 m基础沿y方向的长度b = 2W1 = 0.80 m埋深 d = 900mmas = 80mm材料特性:混凝土: C25钢筋: HRB335考虑最小配筋率四、荷载数据1作用在基础顶部的基本组合荷载竖向荷载 F = 50.00kN基础自重和基础上的土重为:G = 1.35×m×l×b×d = 1.35×20.0×0.80×0.80×0.90 = 15.55kNMx = 0.00kN·mMy = 0.00kN·mVx = 0.00kNVy = 0.00kN2作用在基础底部的弯矩设计值绕X轴弯矩: M0x = Mx - Vy×(H1 + H2) = 0.00 - 0.00 ×(0.20 + 0.00) = 0.00kN·m绕Y轴弯矩: M0y = My + Vx×(H1 + H2) = 0.00 + 0.00 × (0.20 + 0.00) = 0.00kN·m3折减系数Ks = 1.35五、修正地基承载力修正后的地基承载力特征值 fa = 100.00 kPa六、轴心荷载作用下地基承载力验算pk = (FkGk)/A其中:A = 0.80×0.80 = 0.64m2Fk = F/Ks = 50.00/1.35 = 37.04kN Gk = G/1.35 = 15.55/1.35 = 11.52kN pk = 75.87 kPa fa, 满足要求七、基础抗冲切验算计算公式:按建筑地基基础设计规范(GB 50007-2011)下列公式验算:Fl 0.7bhp ft am h0(8.2.7-1) am = (atab)/2(8.2.7-2) Fl = pj Al(8.2.7-3) 1基底最大净反力基底平均净反力pc = 78.12 kPa基底最大净反力pj = pjx + pjy - pc = 78.13 + 78.12 - 78.12 = 78.13 kPa2柱子对基础的冲切验算:X方向:Alx = 0.0871m2Flx = pj×Alx = 78.13 × 0.0871 = 6.80kNab = Minbc + 2×h0, b = Min0.30 + 2×0.12, 0.80 = 0.54mamx = (at+ab)/2 = (0.30 + 0.54)/2 = 0.42mFlx 0.7×hp×ft×amx×h0 = 0.7×1.00×1.27×0.42×0.12×1000= 44.81kN, 满足要求Y方向:Aly = 0.0871m2Fly = pj×Aly = 78.13 × 0.0871 = 6.80kNab = Minac + 2×h0, a = Min0.30 + 2×0.12, 0.80 = 0.54mamy = (at+ab)/2 = (0.30 + 0.54)/2 = 0.42mFly 0.7×hp×ft×amy×h0 = 0.7×1.00×1.27×0.42×0.12×1000= 44.81kN, 满足要求3变阶处基础的冲切验算:X方向:Alx = 0.1456m2Flx = pj×Alx = 78.13 × 0.1456 = 11.38kNab = Minbc + 2×h0, b = Min0.00 + 2×0.12, 0.80 = 0.24mamx = (at+ab)/2 = (0.00 + 0.24)/2 = 0.12mFlx 0.7×hp×ft×amx×h0 = 0.7×1.00×1.27×0.12×0.12×1000= 12.80kN, 满足要求Y方向:Aly = 0.1456m2Fly = pj×Aly = 78.13 × 0.1456 = 11.38kNab = Minac + 2×h0, a = Min0.00 + 2×0.12, 0.80 = 0.24mamy = (at+ab)/2 = (0.00 + 0.24)/2 = 0.12mFly 0.7×hp×ft×amy×h0 = 0.7×1.00×1.27×0.12×0.12×1000= 12.80kN, 满足要求八、基础局部受压验算计算公式:混凝土结构设计规范(A.5.1-1)Fl w×l×fcc×Aln局部荷载设计值:Fl = 50.00kN混凝土局部受压面积:Aln = bc×hc = 0.30×0.30 = 0.09m2混凝土受压时计算底面积:Ab = 0.00m2混凝土受压时强度提高系数:w×bl×fcc×Aln = 1.00×0.00×10115.00×0.09 = 0.00 kN < Fl = 50.00kN 不满足要求!九、受弯计算结果1柱根部受弯计算:轴心荷载作用下截面基底反力设计值:-截面处弯矩设计值:a1 = 0.80/2 - 0.30/2 = 0.25= 3.33kN·mX方向计算面积:102.88mm2根据混凝土结构设计规范第9.5.2条,取最小配筋率为0.15,X方向构造配筋面积:240.00mm2-截面处弯矩设计值:a1 = 0.80/2 - 0.30/2 = 0.25= 3.33kN·mY方向计算面积:102.88mm2根据混凝土结构设计规范第9.5.2条,取最小配筋率为0.15,Y方向构造配筋面积:240.00mm22变阶处受弯计算:轴心荷载作用下截面基底反力设计值:-截面处弯矩设计值:a1 = 0.80/2 - 0.00/2 = 0.40= 3.33kN·mX方向计算面积:102.88mm2根据混凝土结构设计规范第9.5.2条,取最小配筋率为0.15,X方向构造配筋面积:240.00mm2-截面处弯矩设计值:a1 = 0.80/2 - 0.00/2 = 0.40= 3.33kN·mY方向计算面积:102.88mm2根据混凝土结构设计规范第9.5.2条,取最小配筋率为0.15,Y方向构造配筋面积:240.00mm2 X方向弯矩计算结果:计算面积:240.00mm2采用方案:B10200X方向钢筋总根数为: 5实配面积:392.70mm2 Y方向弯矩计算结果:计算面积:240.00mm2采用方案:B10200Y方向钢筋总根数为: 5实配面积:392.70mm2十、施工配筋图(详见基础施工图)