365466--某电器公司电线电缆插头插座产品设计参考手册--gm03.pdf
Chaus Electrical Company Limited 電線電纜 one-time testing, evaluation or inspection using criteria developed by a federal, state or local authority or to satisfy product performance and/or installation requirements specified in regulations or standards of others; developing requirements, tests or other data for use by other Applicants in establishing Listing (or other) and Follow-Up Service on a product; research investigations; or work for a government agency TYPE L SERVICE A form of Follow-Up Service applicable to products or systems for which UL conducts FUS factory inspections on the basis of the number of UL certification marks being used by a manufacturer on a product or system. TYPE R SERVICE A form of Follow-Up Service applicable to products or systems for which UL conducts FUS factory inspections on a periodic calendar basis with a minimum of four inspections per year. UNLISTED COMPONENT A component used in a Listed (or other) product which is separately investigated for a product manufacturer as a component of the complete product using appropriate requirements applicable for Listing (or other) of the part, but for which no published recognition is requested. VARIATION NOTICE (VN) A document used by ULs Field Operations to record observed differences between a product or manufacturing process and a description in a FUS Procedure. 2. UL 產品概況產品概況 因种類較多, 待后續補充 3. 申請者資料申請者資料 只選擇部分列出 PDF created with FinePrint pdfFactory trial version Chaus Electrical Company Limited 電線電纜 These devices have been evaluated when molded on the specific conductor size and type specified in the procedure. Use with any other size of or type cord may require additional evaluation. These fittings should be used only within their electrical rating. 5.4.4.1 NEMA Configuration (Section 1). 1) SP-002, -002PIssued: 1989.08.01, Revised: 2001.01.03 Configuration: 1-15P Cord:18, 16AWG Electrical:10, 13A C-UL:Yes. Cord type: USL - Listed and/or CNL - C-UL or CSA Certified: 18AWG/2C: SPT-1, NISPT-1, SJT, SPT-2, NISPT-2 16AWG/2C: SJT, SPT-2, NISPT-2 Conditions of Acceptability: Be only used on special use power supply cords due to large face dimensions. Marking: A special-use non-detachable power supply cord intended for use with a toy transformer or electric toy shall be marked “For use with toy transformers or electric toys” or an equivalent statement. 2) SP-003 Configuration: 5-15P Cord:18, 16, 14, 12AWG Electrical:10, 13, 15, 15A C-UL:Yes. Cord type: USL - Listed and/or CNL - C-UL or CSA Certified: 18AWG/3C: SPT-1, NISPT-1, SPT-2, NISPT-2, SPT-3, SVT, SJT, ST 16AWG/3C: SPT-2, NISPT-2, SPT-3, SJT, ST 14AWG/3C: SPT-3, SJT, ST PDF created with FinePrint pdfFactory trial version Chaus Electrical Company Limited 電線電纜 These devices have been evaluated when molded on the specific conductor size and type specified in the procedure. Use with any other size of or type cord may require additional evaluation. These fittings should be used only within their electrical rating. Products: 1) SP-018 Configuration: 1-15R Cord:16, 14AWG Electrical:13, 15A C-UL:Yes. Cord type: USL - Listed and/or CNL - C-UL or CSA Certified: 16AWG/2C:SPT-2, NISPT-2, SJT, SJTW, HPN(15A) 14AWG/2C:SJT, SJTW Marking: “Cord Set Out Door Use” 2) SP-019 Configuration: 1-15R, 3 outlet Cord:16AWG Electrical:13A C-UL:Yes. Cord type: USL - Listed and/or CNL - C-UL or CSA Certified: 16AWG/2C:SPT-2, NISPT-2 Marking: “Cord Set General Use”, R/C Cord Tag Required. 3) SP-032 Configuration: 5-15R, 3 outlet Cord:16, 14, 12AWG Electrical:13, 15, 15A C-UL:Yes. Cord type: USL - Listed and/or CNL - C-UL or CSA Certified: 16AWG/3C:SJT, SJTW, SPT-2, SPT-3, NISPT-2 PDF created with FinePrint pdfFactory trial version Chaus Electrical Company Limited 電線電纜 These devices have been evaluated when molded on the specific conductor size and type specified in the procedure. Use with any other size of or type cord may require additional evaluation and should be sent to UL. These fittings should be used only within their electrical rating. Products: 1) SP-011 Configuration: Phenolic Cord:18AWG/2C PDF created with FinePrint pdfFactory trial version Chaus Electrical Company Limited 電線電纜 Tinned copper conductors only. Insulation: No.1812AWG range: Minimum average thickness 38 mils, minimum at any point 31mils. PDF created with FinePrint pdfFactory trial version Chaus Electrical Company Limited 電線電纜 1969+AMD2307: 1977+AMD4045: 1982+AMD5809: 1987 +AMD6144: 1989+Supplement No.1: 1960+Supplement No.2: 1987. Specification for safety requirements for two-pole and earthing pin plugs, socket-outlets and socket-outlet adaptors. Fitted cable: H05VV-F3X 2.5VDE Approved H05VV-F3X 1.5VDE Approved 2) CS-004, 5A, 250V Applicable standards:(同 CS-006) Fitted cable: H05VV-F3X 0.75VDE Approved Appliance connector (Optional) CE-601 10A, 250V, Provided with cord guard, VDE approved 3) BS-01, 13A Applicable standards: BS1363 Part1: 1995, 13A plugs, socket outlets, adaptors and connection units, part1. Specification